Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2024 a 5 de janeiro de 2025.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

 

Analysis of the electrical characteristics and surge protection of EHV transmission lines supported by tall towers

dc.contributor.authorPinto, Andre Jinno G.
dc.contributor.authorCosta, Eduardo Coelho M. [UNESP]
dc.contributor.authorKurokawa, Sergio [UNESP]
dc.contributor.authorMonteiro, Jose Humberto A.
dc.contributor.authorFranco, Jorge Luiz de
dc.contributor.authorPissolato, Jose
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-12-03T13:09:14Z
dc.date.available2014-12-03T13:09:14Z
dc.date.issued2014-05-01
dc.description.abstractThe electrical characteristics of a new 280-m-tall transmission line are analyzed. The geometrical distance of the phases, wires height and physical structure of the line are intrinsic associated with its electrical performance in steady state as well as in transient conditions. Thus, a frequency-domain analysis is proposed comparing the longitudinal and transversal electrical parameters calculated from the tall transmission line with the same parameters obtained for a conventional 440-kV line. An adapted method for the mutual parameters is proposed to calculate the shunt capacitances considering two dielectrics between the wires and ground (air and forest), taking into account that the new transmission system has not a corridor, as usually observed in conventional lines. A second analysis is performed based on both lines modeling and time-domain simulations using the EMTP. Electromagnetic transient simulations from an atmospheric impulse shows that the tall transmission line has a major transient overvoltage than a conventional line. In sequence, an alternative surge protection is proposed using metal-oxide arresters connected directly at the phases, in parallel with the line insulators. The main objective of this technical report is to evaluate the electrical characteristics of the new transmission system using tall structures and, by this means, to highlight the possible variations concerning its operation and transient response. (C) 2013 Elsevier Ltd. All rights reserved.en
dc.description.affiliationUniv Campinas Unicamp, High Voltage Lab, Campinas, SP, Brazil
dc.description.affiliationUniv Estadual Paulista Unesp, Fac Engn Ilha Solteira Feis, Ilha Solteira, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista Unesp, Fac Engn Ilha Solteira Feis, Ilha Solteira, SP, Brazil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdCAPES: 4570-11-1
dc.description.sponsorshipIdFAPESP: 13/00974-5
dc.format.extent358-365
dc.identifierhttp://dx.doi.org/10.1016/j.ijepes.2013.12.015
dc.identifier.citationInternational Journal Of Electrical Power & Energy Systems. Oxford: Elsevier Sci Ltd, v. 57, p. 358-365, 2014.
dc.identifier.doi10.1016/j.ijepes.2013.12.015
dc.identifier.issn0142-0615
dc.identifier.lattes4830845230549223
dc.identifier.urihttp://hdl.handle.net/11449/112117
dc.identifier.wosWOS:000331772700038
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofInternational Journal of Electrical Power & Energy Systems
dc.relation.ispartofjcr3.610
dc.relation.ispartofsjr1,276
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectTall transmission towersen
dc.subjectFrequency-domain analysisen
dc.subjectElectromagnetic transientsen
dc.subjectLightning performanceen
dc.subjectSurge arrestersen
dc.titleAnalysis of the electrical characteristics and surge protection of EHV transmission lines supported by tall towersen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
unesp.author.lattes4830845230549223
unesp.author.orcid0000-0002-9263-980X[3]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentEngenharia Elétrica - FEISpt