Evaluation of a new intraoral paralleling device for creating guiding planes: A pilot study

dc.contributor.authorBorges, Alexandre Luiz Souto [UNESP]
dc.contributor.authorBorges, Alessandra Bühler [UNESP]
dc.contributor.authorUemura, Eduardo Shigueyuki [UNESP]
dc.contributor.authorPaes-Júnior, Tarcisio José de Arruda [UNESP]
dc.contributor.authorTango, Rubens Nisie [UNESP]
dc.contributor.authorde Araújo, José Eduardo Junho [UNESP]
dc.contributor.authorKimpara, Estevão Tomomitsu [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:24:37Z
dc.date.available2014-05-27T11:24:37Z
dc.date.issued2010-01-01
dc.description.abstractAim: The aim of the study was to assess the accuracy of a new intraoral paralleling device for creating proximal guiding planes for removable partial dental prostheses. Methods and Materials: Thirty gypsum casts were divided into two groups in which the proximal surfaces of selected teeth were prepared using either a surveying device (Group 1) or the new ParalAB paralleling device (Group 2). In each cast guiding planes were prepared on the distal surface of the maxillary left canine (A), on the mesial and distal surfaces of the maxillary left second molar (B and C), and on the distal surface of the maxillary right canine (D). Each prepared surface formed an angle related to the occlusal plane that was measured five times and averaged by one operator using a tridimensional coordinate machine. Results: The mean guiding plane angles (± standard deviation) for the prepared surfaces were A=91.82° (±0.48°, B=90.47° (±0.47°, C=90.21° (±0.76°, and D=90.50° (±0.73°) for the dental surveyor (Group 1) and A=92.18° (±0.87°), B=90.90° (±0.85°), C=90.07° (±0.92°), and D=90.66° (±0.76°) for the ParalAB paralleling device (Group 2). A two-way ANOVA, Tukey's, and Levène's tests (at p<0.05) revealed statistically significant differences among surfaces prepared by both groups and that one surface Conclusions: The ParalAB device was able to prepare parallel surfaces and despite significant difference between groups, the ParalAB presented a small deviation from absolute parallelism and can be considered a valid method to transfer guide plans in the fabrication of removable partial dentures. Clinical Significance: The preparation of suitable guiding planes on abutment teeth during the fabrication of removable partial dentures is dependent on the ability of the operator and requires considerable chair time. When multiple teeth are involved, achieving parallelism between abutment surfaces can be technically challenging, especially in posterior regions of the mouth. The ParalAB prototype intraoral paralleling device can aid the clinician during the preparation of accurate guiding planes with a minimum degree of occlusal divergence. © 2010 Seer Publishing LLC.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics School of Dentistry of São José dos Campos São Paulo State University-UNES, São José dos Campos, São Paulo
dc.description.affiliationDepartment of Restorative Dentistry School of Dentistry of São José dos Campos São Paulo State University-UNESP, São José dos Campos, São Paulo
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics School of Dentistry of São José dos Campos São Paulo State University-UNES, São José dos Campos, São Paulo
dc.description.affiliationUnespDepartment of Restorative Dentistry School of Dentistry of São José dos Campos São Paulo State University-UNESP, São José dos Campos, São Paulo
dc.format.extent65-72
dc.identifierhttp://www.researchgate.net/profile/Alexandre_Borges3/publication/41124349_Evaluation_of_a_new_intraoral_paralleling_device_for_creating_guiding_planes_a_pilot_study/file/d912f50ed9f17d57d1.pdf
dc.identifier.citationJournal of Contemporary Dental Practice, v. 11, n. 1, p. 65-72, 2010.
dc.identifier.file2-s2.0-80053423534.pdf
dc.identifier.issn1526-3711
dc.identifier.lattes6043459304176015
dc.identifier.lattes6960470053037905
dc.identifier.lattes1843509097437262
dc.identifier.lattes9138716680440603
dc.identifier.lattes0967916388665754
dc.identifier.orcid0000-0002-5707-7565
dc.identifier.orcid0000-0003-0586-4644
dc.identifier.orcid0000-0003-0946-1826
dc.identifier.scopus2-s2.0-80053423534
dc.identifier.scopus2-s2.0-77950487600
dc.identifier.urihttp://hdl.handle.net/11449/71553
dc.language.isoeng
dc.relation.ispartofJournal of Contemporary Dental Practice
dc.relation.ispartofsjr0,263
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectGuide plane
dc.subjectIntraoral surveyor
dc.subjectPath of insertion
dc.subjectRemovable partial denture
dc.titleEvaluation of a new intraoral paralleling device for creating guiding planes: A pilot studyen
dc.typeArtigo
unesp.author.lattes6043459304176015[1]
unesp.author.lattes6960470053037905[2]
unesp.author.lattes1843509097437262
unesp.author.lattes9138716680440603[5]
unesp.author.lattes0967916388665754[7]
unesp.author.orcid0000-0002-5707-7565[1]
unesp.author.orcid0000-0001-8446-0474[4]
unesp.author.orcid0000-0001-7686-089X[2]
unesp.author.orcid0000-0003-0586-4644[7]
unesp.author.orcid0000-0003-0946-1826[5]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campospt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-80053423534.pdf
Tamanho:
1.4 MB
Formato:
Adobe Portable Document Format