Sensitive determination of water insoluble dyes used as marking of commercial petroleum products using high-performance liquid chromatography with electrochemical detection
dc.contributor.author | Trindade, Magno Aparecido Gonçalves [UNESP] | |
dc.contributor.author | Zanoni, Maria Valnice Boldrin [UNESP] | |
dc.contributor.author | Matysik, Frank-Michael | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.contributor.institution | Chemo- and Biosensors | |
dc.date.accessioned | 2022-04-28T21:01:16Z | |
dc.date.available | 2022-04-28T21:01:16Z | |
dc.date.issued | 2010-05-01 | |
dc.description.abstract | This paper describes an analytical method using high-performance liquid chromatographic (HPLC) separation coupled with electrochemical detection to detect three dyes, Solvent Blue 14 (SB-14), Solvent Blue 35 (SB-35) and Solvent Red 24 (SR-24). The dyes were eluted and separated using a reversed-phase column (C-8) under isocratic elution with the mobile phase containing a mixture of acetonitrile/ammonium acetate (5.0 mmol L -1) at the ratio of 75:25 (v/v). Two sample pretreatment methods were tested and successfully applied to quantify SB14, SB-35 and SR24 dyes in gasoline samples. The proposed method was simple, fast and suitable to detect and quantify marker dyes in gasoline sample at low concentration. © 2010 Wiley-VCH Verlag GmbH &Co. KGaA, Weinheim. | en |
dc.description.affiliation | Department of Analytical Chemistry Institute of Chemistry Araraquara, SãoPauloState University - UNESP, Rua Francisco Degni, s/n, Bairro Quitandinha, 14800-900, Araraquara, SP | |
dc.description.affiliation | University of Regensburg Institute of Analytical Chemistry Chemo- and Biosensors, 93040 Regensburg | |
dc.description.affiliationUnesp | Department of Analytical Chemistry Institute of Chemistry Araraquara, SãoPauloState University - UNESP, Rua Francisco Degni, s/n, Bairro Quitandinha, 14800-900, Araraquara, SP | |
dc.format.extent | 955-962 | |
dc.identifier | http://dx.doi.org/10.1002/elan.200900500 | |
dc.identifier.citation | Electroanalysis, v. 22, n. 9, p. 955-962, 2010. | |
dc.identifier.doi | 10.1002/elan.200900500 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.issn | 1521-4109 | |
dc.identifier.scopus | 2-s2.0-77951483590 | |
dc.identifier.uri | http://hdl.handle.net/11449/225836 | |
dc.language.iso | eng | |
dc.relation.ispartof | Electroanalysis | |
dc.source | Scopus | |
dc.subject | Dyes | |
dc.subject | Electrochemical detector | |
dc.subject | Fuel | |
dc.subject | Liquid chromatography | |
dc.subject | Marker dyes | |
dc.subject | Petrol sample | |
dc.subject | Solvent dyes | |
dc.title | Sensitive determination of water insoluble dyes used as marking of commercial petroleum products using high-performance liquid chromatography with electrochemical detection | en |
dc.type | Artigo | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |