Atomic pair distribution function at the Brazilian Synchrotron Light Laboratory: Application to the Pb1-xLaxZr0.40Ti0.60O3 ferroelectric system

dc.contributor.authorSaleta, M. E.
dc.contributor.authorEleotério, M.
dc.contributor.authorMesquita, A. [UNESP]
dc.contributor.authorMastelaro, V. R.
dc.contributor.authorGranado, E.
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionLaboratório Nacional de Luz Síncrotron
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionCNEA
dc.date.accessioned2018-12-11T16:49:14Z
dc.date.available2018-12-11T16:49:14Z
dc.date.issued2017-09-01
dc.description.abstractThis work reports the setting up of the X-ray diffraction and spectroscopy beamline at the Brazilian Synchrotron Light Laboratory for performing total scattering experiments to be analyzed by atomic pair distribution function (PDF) studies. The results of a PDF refinement for Al2O3 standard are presented and compared with data acquired at a beamline of the Advanced Photon Source, where it is common to perform this type of experiment. A preliminary characterization of the Pb1-xLaxZr0.40Ti0.60O3 ferroelectric system, with x = 0.11, 0.12 and 0.15, is also shown.A setup for total scattering experiments at the multi-purpose XDS beamline of the Brazilian Synchrotron Light Laboratory (LNLS) is described. Also, a preliminary characterization of the Pb1-xLaxZr0.40Ti0.60O3 (x = 0.11, 0.12 and 0.15) ferroelectric system using pair distribution function analysis is presented.en
dc.description.affiliationInstituto de Física 'Gleb Wataghin' Universidade de Campinas (UNICAMP)
dc.description.affiliationLaboratório Nacional de Luz Síncrotron, Caixa Postal 6192
dc.description.affiliationInstituto Geociências and Ciências Exatas Universidade Estadual Paulista (UNESP)
dc.description.affiliationInstituto de Física de São Carlos Universidade de São Paulo, CP 369
dc.description.affiliationCONICET - Centro Atómico Bariloche CNEA
dc.description.affiliationUnespInstituto Geociências and Ciências Exatas Universidade Estadual Paulista (UNESP)
dc.format.extent1098-1104
dc.identifierhttp://dx.doi.org/10.1107/S1600577517008633
dc.identifier.citationJournal of Synchrotron Radiation, v. 24, n. 5, p. 1098-1104, 2017.
dc.identifier.doi10.1107/S1600577517008633
dc.identifier.file2-s2.0-85028710538.pdf
dc.identifier.issn1600-5775
dc.identifier.issn0909-0495
dc.identifier.scopus2-s2.0-85028710538
dc.identifier.urihttp://hdl.handle.net/11449/170095
dc.language.isoeng
dc.relation.ispartofJournal of Synchrotron Radiation
dc.relation.ispartofsjr1,650
dc.relation.ispartofsjr1,650
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectatomic pair distribution function
dc.subjectferroelectric relaxor
dc.subjectX-ray total scattering
dc.titleAtomic pair distribution function at the Brazilian Synchrotron Light Laboratory: Application to the Pb1-xLaxZr0.40Ti0.60O3 ferroelectric systemen
dc.typeArtigo
unesp.author.lattes2835864951583089[3]
unesp.author.orcid0000-0001-8524-0959[3]

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-85028710538.pdf
Tamanho:
1.43 MB
Formato:
Adobe Portable Document Format
Descrição:

Coleções