Assessment of the ergonomic design of diagnostic ultrasound transducers through wrist movements and subjective evaluation

dc.contributor.authorPaschoarelli, Luis Carlos [UNESP]
dc.contributor.authorde Oliveira, Ana Beatriz
dc.contributor.authorCote Gil Coury, Helenice Jane
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:13:00Z
dc.date.available2014-05-20T13:13:00Z
dc.date.issued2008-11-01
dc.description.abstractThis study presents procedures for assessing the redesign of ultrasound transducers. Wrist movements were recorded using elect rogoniometers. Perceptions of discomfort and acceptability of the new transducers were evaluated. The assessment was performed in two phases: (1) design of the product and an initial evaluation of movements during simulated activity with one mock-up and with two commercially available transducers; (2) project review and the development and evaluation of new mock-ups (2 and 3) by non-experienced subjects, and subjective assessment of all the mock-ups and commercial transducers by non-experienced subjects and trained physicians. First mock-up did not present improvements regarding the wrist movements and the time spent within safe amplitudes. The project review resulted in two new mock-ups that led to lower average amplitudes of movements (p <= 0,05) and more time spent within safe amplitudes. Thus, the application of quantitative (recording movements) and subjective (perceptions of discomfort and acceptability) approaches allowed for subsequent redesigns of the transducers that led to improvement of the product under evaluation.en
dc.description.affiliationUniversidade Federal de São Carlos (UFSCar), Dept Phys Therapy, BR-13565905 São Carlos, SP, Brazil
dc.description.affiliationSão Paulo State Univ, Fac Architecture Arts & Commun, Dept Ind Design, Bauru, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Fac Architecture Arts & Commun, Dept Ind Design, Bauru, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.format.extent999-1006
dc.identifierhttp://dx.doi.org/10.1016/j.ergon.2008.01.013
dc.identifier.citationInternational Journal of Industrial Ergonomics. Amsterdam: Elsevier B.V., v. 38, n. 11-12, p. 999-1006, 2008.
dc.identifier.doi10.1016/j.ergon.2008.01.013
dc.identifier.issn0169-8141
dc.identifier.lattes8521603444193259
dc.identifier.urihttp://hdl.handle.net/11449/915
dc.identifier.wosWOS:000261543600014
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofInternational Journal of Industrial Ergonomics
dc.relation.ispartofjcr1.429
dc.relation.ispartofsjr0,795
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectUsabilityen
dc.subjectRedesignen
dc.subjectElectrogoniometryen
dc.subjectAcceptabilityen
dc.subjectDiscomforten
dc.subjectUltrasonographyen
dc.titleAssessment of the ergonomic design of diagnostic ultrasound transducers through wrist movements and subjective evaluationen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
unesp.author.lattes8521603444193259
unesp.author.orcid0000-0002-4685-0508[1]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Arquitetura, Artes, Comunicação e Design, Baurupt
unesp.departmentDesign - FAACpt

Arquivos

Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: