Electrochemical sensing using magnetic molecularly imprinted polymer particles previously captured by a magneto-sensor
dc.contributor.author | Ruiz-Córdova, Gerson A. [UNESP] | |
dc.contributor.author | Khan, Sabir [UNESP] | |
dc.contributor.author | Gonçalves, Luís Moreira | |
dc.contributor.author | Pividori, Maria Isabel | |
dc.contributor.author | Picasso, Gino | |
dc.contributor.author | Sotomayor, Maria Del Pilar T. [UNESP] | |
dc.contributor.institution | National University of Engineering | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM) | |
dc.contributor.institution | Universidade do Porto | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Universitat Autònoma de Barcelona | |
dc.date.accessioned | 2018-12-11T17:17:12Z | |
dc.date.available | 2018-12-11T17:17:12Z | |
dc.date.issued | 2018-05-01 | |
dc.description.abstract | The determination of 1-chloro-2,4-dinitrobenzene (CDNB) was used as a proof-of-concept to a simple analytical practical configuration applying magnetic molecularly imprinted particles (mag-MIPs). Mag-MIPs were captured from an emulsion by a home-made magneto-sensor (where a small magnet was entrapped by a graphite-epoxy composite) and then, this sensor, was transferred to the solution containing the analyte, where, after binding to the mag-MIPs, the analyte was directly analysed using differential pulse voltammetry (DPV) since the magneto-sensor acted as the working electrode. After optimization, a detection limit of 6.0 μmol L−1 with a RSD of 2.7% was achieved along with suitable recoveries and selectivity. This methodology offers a different approach for electroanalytical methodologies using mag-MIPs. | en |
dc.description.affiliation | Laboratory of Physical Chemistry Research Faculty of Sciences National University of Engineering | |
dc.description.affiliation | Department of Analytical Chemistry Institute of Chemistry UNESP – Univ Estadual Paulista | |
dc.description.affiliation | National Institute for Alternative Technologies of Detection Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM) | |
dc.description.affiliation | REQUIMTE/LAQV Faculdade de Ciências Universidade do Porto | |
dc.description.affiliation | Departamento de Química Fundamental Instituto de Química Universidade de São Paulo (USP) | |
dc.description.affiliation | Universitat Autònoma de Barcelona | |
dc.description.affiliationUnesp | Department of Analytical Chemistry Institute of Chemistry UNESP – Univ Estadual Paulista | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description.sponsorship | Ministerio de Economía y Competitividad | |
dc.description.sponsorship | Fundació Catalana de Trasplantament | |
dc.description.sponsorshipId | FAPESP: 2014/25264-3, 2014/50945-4 | |
dc.description.sponsorshipId | FAPESP: 2016/06926-0 | |
dc.description.sponsorshipId | CNPq: 303690/2012-7 | |
dc.description.sponsorshipId | CNPq: 465571/2014-0 | |
dc.description.sponsorshipId | Ministerio de Economía y Competitividad: BIO2016-75751-R | |
dc.description.sponsorshipId | Fundació Catalana de Trasplantament: FCT/13277/4/8/2015S | |
dc.description.sponsorshipId | Fundació Catalana de Trasplantament: SFRH/BPD/76544/2011 | |
dc.format.extent | 19-23 | |
dc.identifier | http://dx.doi.org/10.1016/j.talanta.2017.12.085 | |
dc.identifier.citation | Talanta, v. 181, p. 19-23. | |
dc.identifier.doi | 10.1016/j.talanta.2017.12.085 | |
dc.identifier.file | 2-s2.0-85039955235.pdf | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.scopus | 2-s2.0-85039955235 | |
dc.identifier.uri | http://hdl.handle.net/11449/175712 | |
dc.language.iso | eng | |
dc.relation.ispartof | Talanta | |
dc.relation.ispartofsjr | 1,186 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Scopus | |
dc.subject | 2,4-Dinitrochlorobenzene (CDNB) | |
dc.subject | Electroanalysis | |
dc.subject | Magnetic beads | |
dc.subject | Modified working electrode | |
dc.subject | Nanoparticles | |
dc.subject | Stripping voltammetry | |
dc.title | Electrochemical sensing using magnetic molecularly imprinted polymer particles previously captured by a magneto-sensor | en |
dc.type | Artigo | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- 2-s2.0-85039955235.pdf
- Tamanho:
- 627.48 KB
- Formato:
- Adobe Portable Document Format
- Descrição: