Immunosensors made with layer-by-layer films on chitosan/gold nanoparticle matrices to detect d-dimer as biomarker for venous thromboembolism
dc.contributor.author | Rodrigues, Valquiria C. | |
dc.contributor.author | Moraes, Marli L. | |
dc.contributor.author | Soares, Juliana C. | |
dc.contributor.author | Soares, Andrey C. | |
dc.contributor.author | Sanfelice, Rafaela | |
dc.contributor.author | Deffune, Elenice [UNESP] | |
dc.contributor.author | Oliveira, Osvaldo N. | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Federal University of the Triângulo Mineiro | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2018-12-11T17:21:08Z | |
dc.date.available | 2018-12-11T17:21:08Z | |
dc.date.issued | 2018-01-01 | |
dc.description.abstract | We report on immunosensors to detect D-dimer, a biomarker of venous thromboembolism, which are made with layer-bylayer (LbL) films containing immobilized anti-D-dimer monoclonal antibody alternated with a layer of chitosan/gold nanoparticles (AuNpChi). Detection was due to irreversible adsorption of the antigen D-dimer on its corresponding antibody according to a Langmuir-Freundlich model, thus giving rise to ellipsoidal structures in scanning electron microscopy images whose size and number increased with D-dimer concentration. The chemical groups involved in the adsorption process were inferred from polarization-modulated infrared reflection absorption (PM-IRRAS) through changes in the amide and carbonyl bands. Detection of D-dimer was made with electrical impedance spectroscopy, electrochemical impedance spectroscopy and cyclic voltammetry. The latter was the most sensitive with a detection limit of 9 × 10-4 μg/mL, sensitivity of 0.27 × 10-6A/μgmL-1 with linear increase from 0 to 1 μg/mL. The selectivity of the immunosensor made with AuNpChi/anti-Ddimer film was verified by noting negligible changes in the cyclic voltammograms when exposed to typical interferents in biological fluids. | en |
dc.description.affiliation | São Carlos Institute of Physics University of São Paulo | |
dc.description.affiliation | Federal University of São Paulo Unifesp Campus São José Dos Campos | |
dc.description.affiliation | Department of Chemical Engineering Federal University of the Triângulo Mineiro | |
dc.description.affiliation | Department of Urology Medical School UNESP | |
dc.description.affiliationUnesp | Department of Urology Medical School UNESP | |
dc.format.extent | 891-896 | |
dc.identifier | http://dx.doi.org/10.1246/bcsj.20180019 | |
dc.identifier.citation | Bulletin of the Chemical Society of Japan, v. 91, n. 6, p. 891-896, 2018. | |
dc.identifier.doi | 10.1246/bcsj.20180019 | |
dc.identifier.issn | 1348-0634 | |
dc.identifier.issn | 0009-2673 | |
dc.identifier.scopus | 2-s2.0-85049117792 | |
dc.identifier.uri | http://hdl.handle.net/11449/176511 | |
dc.language.iso | eng | |
dc.relation.ispartof | Bulletin of the Chemical Society of Japan | |
dc.relation.ispartofsjr | 0,999 | |
dc.relation.ispartofsjr | 0,999 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Scopus | |
dc.subject | D-dimer | |
dc.subject | Immunosensor | |
dc.subject | Layer-by-layer (LbL) film | |
dc.title | Immunosensors made with layer-by-layer films on chitosan/gold nanoparticle matrices to detect d-dimer as biomarker for venous thromboembolism | en |
dc.type | Artigo |