Implant-retained finger prosthesis with modified retention system

dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorSantos, Daniela Micheline dos [UNESP]
dc.contributor.authorAmoroso, Andressa Paschoal
dc.contributor.authorGennari Filho, Humberto [UNESP]
dc.contributor.authorDekon, Stefan Fiuza de Carvalho [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-12-03T13:11:44Z
dc.date.available2014-12-03T13:11:44Z
dc.date.issued2013-08-01
dc.description.abstractBackground: Amputations affect both the physical and the psychological aspects of an individual, causing significant impact on self-esteem. The main causes of finger amputations are work-related accidents with dangerous machinery, road traffic accidents, and animal bites, as well as systemic diseases such as diabetes. This report aims to describe a simple technique for fabrication of implant-retained finger prosthesis with a modified base of the retention system.Case Description and Methods: The O-Ring retention system was used with a modified hexagon-shaped base and a metallic capsule adapted to the acrylic resin to attach the prosthesis to the implant.Findings and Outcomes: The prosthesis was made with silicone, and after osseointegration, it was installed without complications, leading to a patient satisfied with the end result and encouraged to return to social life.en
dc.description.affiliationUniv Estadual Paulista, UNESP, Oral Oncol Ctr, Sao Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, UNESP, Sch Dent Aracatuba, Dept Dent Mat & Prosthesis, Sao Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Oral Oncol Ctr, Sao Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Sch Dent Aracatuba, Dept Dent Mat & Prosthesis, Sao Paulo, Brazil
dc.format.extent324-328
dc.identifierhttp://dx.doi.org/10.1177/0309364612465427
dc.identifier.citationProsthetics And Orthotics International. London: Sage Publications Ltd, v. 37, n. 4, p. 324-328, 2013.
dc.identifier.doi10.1177/0309364612465427
dc.identifier.issn0309-3646
dc.identifier.lattes9719883814872582
dc.identifier.lattes5335208171935802
dc.identifier.lattes3215571441204704
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.urihttp://hdl.handle.net/11449/113489
dc.identifier.wosWOS:000336518200010
dc.language.isoeng
dc.publisherSage Publications Ltd
dc.relation.ispartofProsthetics And Orthotics International
dc.relation.ispartofjcr1.097
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectProsthesisen
dc.subjectimplanten
dc.subjectretention systemen
dc.titleImplant-retained finger prosthesis with modified retention systemen
dc.typeArtigo
dcterms.licensehttp://www.uk.sagepub.com/aboutus/openaccess.htm
dcterms.rightsHolderSage Publications Ltd
unesp.author.lattes9719883814872582
unesp.author.lattes5335208171935802
unesp.author.lattes3215571441204704
unesp.author.orcid0000-0002-3800-3050[1]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araçatubapt

Arquivos