Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection
dc.contributor.author | Ribeiro, Daniela Garcia | |
dc.contributor.author | Pavarina, Ana Claudia [UNESP] | |
dc.contributor.author | Machado, Ana Lucia [UNESP] | |
dc.contributor.author | Giampaolo, Eunice Teresinha | |
dc.contributor.author | Vergani, Carlos Eduardo [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:46:31Z | |
dc.date.available | 2014-05-20T13:46:31Z | |
dc.date.issued | 2008-11-01 | |
dc.description.abstract | Objectives: To evaluate the effect of microwave disinfection on the flexural strength and Vickers hardness of 4 autopolymerized resins (Kooliner [K], Tokuso Rebase Fast [T], Ufi Gel Hard [U], and New Truliner [N]) and 1 denture base resin (Lucitone 550 [L]). Method and Materials: For each material, 48 specimens (64 x 10 x 3.3 mm) were made and divided into 6 equal groups (n = 8). In the control group, specimens were untreated. Before testing, specimens were immersed in 200 mL of distilled water and submitted to disinfection for 1 of the following irradiation times: 1, 2, 3, 4, or 5 minutes. The irradiation procedure was performed twice. The flexural strength was determined using a testing machine MTS-810 and measurements of Vickers hardness were made on Micromet 2100. The values were submitted to ANOVA and Tukey's test (P = .05). Results: The K material showed a significant increase (P = .0010) in flexural strength following 5 minutes of disinfection compared to control specimens. The flexural strength mean values of materials T, U, and N were not significantly affected (P > .05) by disinfection. Compared to the control group, the K material showed a significant increase in hardness (P < .001) following disinfection for 3, 4, and 5 minutes. For material U, disinfection for 4 and 5 minutes produced specimens with significantly increased hardness values (P < .001) compared to the control group. For material N, disinfection for 5 minutes resulted in significantly higher hardness values (P < .001) than the control group. Conclusion: Regardless of the irradiation time, the flexural strength and hardness of the materials evaluated were not detrimentally affected by microwave disinfection. (Quintessence Int 2008;39:833-840) | en |
dc.description.affiliation | São Paulo State Univ, UNESP, Fac Odontol Araraquara, Araraquara Dent Sch,Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Fac Odontol Araraquara, Araraquara Dent Sch,Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, Brazil | |
dc.description.sponsorship | Fundação para o Desenvolvimento da UNESP (FUNDUNESP) | |
dc.description.sponsorshipId | FUNDUNESP: 00252/03-DFP | |
dc.format.extent | 833-840 | |
dc.identifier | http://www.quintpub.com/journals/qi/abstract.php?article_id=3559#.UjDRzsZwp5I | |
dc.identifier.citation | Quintessence International. Hanover Park: Quintessence Publishing Co Inc, v. 39, n. 10, p. 833-840, 2008. | |
dc.identifier.issn | 0033-6572 | |
dc.identifier.lattes | 8867670539105403 | |
dc.identifier.lattes | 8000248781842587 | |
dc.identifier.lattes | 5737127334248549 | |
dc.identifier.lattes | 3003130522427820 | |
dc.identifier.orcid | 0000-0002-7375-4714 | |
dc.identifier.uri | http://hdl.handle.net/11449/16473 | |
dc.identifier.wos | WOS:000261138100007 | |
dc.language.iso | eng | |
dc.publisher | Quintessence Publishing Co Inc | |
dc.relation.ispartof | Quintessence International | |
dc.relation.ispartofjcr | 1.088 | |
dc.relation.ispartofsjr | 0,563 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | acrylic resins | en |
dc.subject | cross infection | en |
dc.subject | disinfection | en |
dc.subject | flexural strength | en |
dc.subject | hardness | en |
dc.subject | microwave | en |
dc.title | Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection | en |
dc.type | Artigo | |
dcterms.license | http://www.quintpub.com/journals/jop/orderreprints.php | |
dcterms.rightsHolder | Quintessence Publishing Co Inc | |
unesp.author.lattes | 8867670539105403[2] | |
unesp.author.lattes | 8000248781842587[3] | |
unesp.author.lattes | 5737127334248549(4) | |
unesp.author.lattes | 3003130522427820[5] | |
unesp.author.orcid | 0000-0002-7375-4714[5] | |
unesp.author.orcid | 0000-0002-9231-1994[2] | |
unesp.author.orcid | 0000-0002-2718-428X[3] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: