Standardization of a NaI(Tl) scintillation detector and its use on environments for Geology teaching in a Brazilian university

dc.contributor.authorBarbosa, Eder Queiroz [UNESP]
dc.contributor.authorBonotto, Daniel Marcos [UNESP]
dc.contributor.authorRoveratti, Gabrielle [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:35:44Z
dc.date.available2018-12-11T17:35:44Z
dc.date.issued2018-02-01
dc.description.abstractThis paper describes analytical protocols adopted for calibrating a portable gamma rays spectrometer using a 2ʺ × 2ʺ NaI(Tl) scintillation detector for performing exploration and environmental surveys. The steps involved the determination of counting times with good accuracy, calibration in energy and concentration, and data conversion to effective dose (Ed) for monitoring the radioactivity levels in the air, for indoor and outdoor environments. The χ2 test was applied to the counting rate data acquired for ten different readings, allowing determine the greater accuracy among them. Some standards yielded values above of the detection limit for calibrating the K, eU, and eTh windows, whereas empirical equations provided satisfactory results. The count rates in these windows were obtained in selected environments related to Geology teaching activities in a Brazilian university. Then, they were converted to Ed, showing the applicability of the adopted procedures for environmental surveys. The radiological monitoring showed two sites exhibiting Ed values above the WHO guideline reference value of 1 mSv/year. The first was in a minerals and rocks museum and the second in a deposit (litoteca) dedicated to the rocks storage. Thus, the members of the public are only occasionally exposed to the natural gamma radiation there. Additionally, the Ed values are much lower than the recommended limit of 20 mSv/year for occupationally exposed individuals.en
dc.description.affiliationInstituto de Geociências e Ciências Exatas-IGCE Universidade Estadual Paulista-UNESP, Av. 24-A No. 1515, P.O. Box 178
dc.description.affiliationUnespInstituto de Geociências e Ciências Exatas-IGCE Universidade Estadual Paulista-UNESP, Av. 24-A No. 1515, P.O. Box 178
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.identifierhttp://dx.doi.org/10.1007/s12665-018-7303-z
dc.identifier.citationEnvironmental Earth Sciences, v. 77, n. 3, 2018.
dc.identifier.doi10.1007/s12665-018-7303-z
dc.identifier.file2-s2.0-85041742763.pdf
dc.identifier.issn1866-6299
dc.identifier.issn1866-6280
dc.identifier.scopus2-s2.0-85041742763
dc.identifier.urihttp://hdl.handle.net/11449/179576
dc.language.isoeng
dc.relation.ispartofEnvironmental Earth Sciences
dc.relation.ispartofsjr0,552
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectCalibration
dc.subjectEffective dose
dc.subjectK, eU, and eTh windows
dc.subjectNaI(Tl) scintillation detector
dc.subjectPortable gamma rays spectrometer
dc.titleStandardization of a NaI(Tl) scintillation detector and its use on environments for Geology teaching in a Brazilian universityen
dc.typeArtigo

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-85041742763.pdf
Tamanho:
1.16 MB
Formato:
Adobe Portable Document Format
Descrição: