Avaliação in vitro da adaptação cervical de coroas totais metálicas, variando os preparos dos términos cervicais, aliviando ou não as superfícies internas das coroas e empregando diferentes cimentos definitivos

dc.contributor.authorBottino, Marco Antonio [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-03-03T11:53:04Z
dc.date.available2015-03-03T11:53:04Z
dc.date.issued1998-12-04
dc.description.abstractEste trabalho avaliou a qualidade das adaptações cervicais de coroas totais metálicas, tendo como fonte de variação: a) o término do ombro cervical do preparo - biselado, inclinado em 1350; reto em 900, chanfro e gume de faca; b) o alívio ou não das superfícies internas das coroas; e, c) os tipos de agente de cimentação permanente, cimentos - fosfato de zinco Harvard; ionômero de vidro Ketac-Cem, policarboxilato de zinco Durelon e resinoso Panavia Ex. Inicialmente, foram confeccionados corpos-de-prova em modelos-padrão de aço inoxidável usinado, de acordo com o tipo de preparo dos términos cervicais experimentais. As cápsulas metálicas de aço inoxidável preparadas, tendo ou não alívio da superfície interna de 30 micrometros até a distância de 0,5 mm do limite do término cervical, justapunham-se precisamente e formavam um conjunto com adaptação e assentamento exatos. Estas foram cimentadas nos corpos-de-prova com os diferentes agentes cimentantes, os quais foram manipulados de acordo com as instruções dos fabricantes. Desenvolveram-se metodologias de reaproveitamento dos corpos-de-prova, estabilidade das cápsulas impedindo seu deslocamento durante a tomada das medidas e mensuração precisa. Concluiu-se que: a) as melhores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros: lâmina de faca, ombro inclinado em 1350 e chanfro; b) as piores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros reto em 900 e degrau em 900 com bisel de 450; c) houve melhora significativa na adaptação quando cápsulas metálicas foram cimentadas com alívio de sua superfície interna; d) os cimentos...(Resumo completo, clicar acesso eletrônico abaixo)pt
dc.description.abstractThis study assessed the quality of cervical adaptation in full metal crowns, with a variation in: a) the type of cervical preparation- beveled shoulder, 135-degree preparation, 90-degree shoulder, chamfer and knife edge; b) internal surfaces of the crowns with or without relief; c) the types of luting agents and their commercial brands- Harvard zinc phosphate, Ketac-Cem glass ionomer, Durelon zinc polycarboxylate and Panavia Ex resinous. Initially, machined stainless steel models were made according to each experimental margin design. Stainless steel metal caps were prepared with or without a 30-micrometer spacing of their internal surfaces, kept away 0.5 mm of the cervical end limit; they were precisely fitted, making a set with exact adaptation and seating. The caps were cemented on the specimens by means of different luting agents , handled according to the manufacturer's instructions. Methods were developed to reuse the specimens. Precise measures were obtained by preventing caps from moving during measurements. The conclusions were: a) the best mean of cervical adaptation, similar to each other , was obtained in standard models with preparations : knife edge, 1350 shoulder and chamfer; b) the worst mean of cervical adaptation, similar between them , was obtained in standard models with: straight shoulder and beveled shoulder; c) there was a significant improvement in adaptation when the metal caps were cemented with relief in their internal surface; d) cements presented decreasing cervical adaption, in the following order: Ketac-Cem, Harvard, Durelon and Panavia Ex; and, e) the methodology used allowed work with positive values of cervical adaptation.en
dc.format.extent151 f. : il. ;
dc.identifier.aleph000126051
dc.identifier.citationBOTTINO, Marco Antonio. Avaliação in vitro da adaptação cervical de coroas totais metálicas, variando os preparos dos términos cervicais, aliviando ou não as superfícies internas das coroas e empregando diferentes cimentos definitivos. 1998. 151 f. Tese (livre-docência) - Universidade Estadual Paulista, Faculdade de Odontologia de São José dos Campos, 1998.
dc.identifier.filebottino_ma_ld_sjc.pdf
dc.identifier.lattes9234456003563666
dc.identifier.urihttp://hdl.handle.net/11449/116116
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso aberto
dc.sourceAleph
dc.subjectPrótese dentáriapt
dc.subjectCimentos dentariospt
dc.subjectCoroas (Odontologia)pt
dc.subjectDental prosthesesen
dc.titleAvaliação in vitro da adaptação cervical de coroas totais metálicas, variando os preparos dos términos cervicais, aliviando ou não as superfícies internas das coroas e empregando diferentes cimentos definitivospt
dc.typeTese de livre-docência
unesp.author.lattes9234456003563666
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campospt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
bottino_ma_ld_sjc.pdf
Tamanho:
286.7 KB
Formato:
Adobe Portable Document Format