dc.description.abstract | In this work, an electrode chemically modified with polypyrrole (PCME) was employed for determination of sulfate in ethanol fuel using a FIA system. The PCME was prepared by polymerization of pyrrole at a glassy carbon electrode by means of cyclic voltammetry technique. An analytical curve from 1.0 x 10−5 to 8.0 x 10−5 mol L−1 was obtained in flow injection system based on the PCME. An amperometric sensibility of 2.3 x 10−3 A mol−1 L and a detection limit of 2.5 x 10−6 mol L−1 were achieved. The proposed method was employed for determination of sulfate ions in commercial samples of ethanol fuel. The results were in good agreement with those obtained by the ionic chromatographic method. | en |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Química Analítica, Instituto de Química de Araraquara, Araraquara, UNESP/IQ/DQA - RUA PROF. FRANCISCO DEGNI, 55, Quitandinha, CEP 14800-900, SP, Brasil | |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Química Analítica, Instituto de Química de Araraquara, Araraquara, UNESP/IQ/DQA - RUA PROF. FRANCISCO DEGNI, 55, Quitandinha, CEP 14800-900, SP, Brasil | |
dc.format.extent | 220-227 | |
dc.identifier | http://www.indianjournals.com/ijor.aspx?target=ijor:jbf&volume=1&issue=2&article=005 | |
dc.identifier.citation | Journal of Biofuels, v. 1, n. 2, p. 220-227, 2010. | |
dc.identifier.doi | 10.5958/j.0976-3015.1.2.027 | |
dc.identifier.issn | 0976-3015 | |
dc.identifier.lattes | 6167204386206414 | |
dc.identifier.lattes | 8477732400095433 | |
dc.identifier.lattes | 0072173018005712 | |
dc.identifier.lattes | 1923726000036625 | |
dc.identifier.lattes | 1183672452248157 | |
dc.identifier.orcid | 0000-0002-2296-1393 | |
dc.identifier.uri | http://hdl.handle.net/11449/123528 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Biofuels | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Currículo Lattes | |
dc.subject | Ethanol fuel | en |
dc.subject | Sulfate determination | en |
dc.subject | Polypyrrole-film | en |
dc.subject | Flow injection analysis | en |
dc.title | Determination of sulfate in ethanol fuel using an electrode chemically modified with polypyrrole by flow injection analysis | en |
dc.type | Artigo | |
unesp.author.lattes | 6167204386206414 | |
unesp.author.lattes | 8477732400095433 | |
unesp.author.lattes | 0072173018005712 | |
unesp.author.lattes | 1923726000036625 | |
unesp.author.lattes | 1183672452248157 | |
unesp.author.orcid | 0000-0002-2296-1393[4] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |