Direct determination of arsenic in sugar by GFAAS with transversely heated graphite atomizer and longitudinal Zeeman-effect background correction

dc.contributor.authorDakuzaku, C. S.
dc.contributor.authorFreschi, GPG
dc.contributor.authorde Moraes, M.
dc.contributor.authorNobrega, J. A.
dc.contributor.authorNeto, JAG
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)
dc.date.accessioned2014-05-20T15:22:17Z
dc.date.available2014-05-20T15:22:17Z
dc.date.issued2001-03-01
dc.description.abstractA method has been developed for the direct determination of As in sugar by graphite furnace atomic absorption spectrometry with a transversely heated graphite atomizer (end-capped THGA) and longitudinal Zeeman-effect background correction. The thermal behavior of As during the pyrolysis and atomization steps was investigated in sugar solutions containing 0.2% (v/v) HNO3 using Pd, Ni, and a mixture of Pd + Mg as the chemical modifiers. For a 60-muL sugar solution, an aliquot of 8% (m/v) in 0.2% (v/v)HNO3 was dispensed into a pre-heated graphite tube at 70 degreesC. Linear analytical curves were obtained in the 0.25 - 1.50-mug L-1 As range. Using 5 mug Pd and a first pyrolysis step at 600 degreesC assisted by air during 40 s, the formation of a large amount of carbonaceous residue inside the atomizer was avoided. The characteristic mass was calculated as 24 pg As and the lifetime of the graphite tube was around 280 firings. The limit of detection (L.O.D.) based on integrated absorbance was 0.08 mug L-1 (4.8 pg As) and the typical relative standard deviation (n = 12) was 7% for a sugar solution containing 0.5 mug L-1. Recoveries of As added to sugar samples varied from 86 to 98%. The accuracy was checked in the direct analysis of eight sugar samples. A paired t-test showed that the results were in agreement at the 95% confidence level with those obtained for acid-digested sugar samples by GFAAS.en
dc.description.affiliationUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil
dc.description.affiliationUniv Fed Sao Carlos, Dept Quim, Sao Carlos, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil
dc.format.extent271-275
dc.identifier.citationAtomic Spectroscopy. Norwalk: Perkin-elmer Corp, v. 22, n. 2, p. 271-275, 2001.
dc.identifier.issn0195-5373
dc.identifier.urihttp://hdl.handle.net/11449/33288
dc.identifier.wosWOS:000168758600001
dc.language.isoeng
dc.publisherPerkin-elmer Corp
dc.relation.ispartofAtomic Spectroscopy
dc.relation.ispartofjcr1.123
dc.relation.ispartofsjr0,327
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleDirect determination of arsenic in sugar by GFAAS with transversely heated graphite atomizer and longitudinal Zeeman-effect background correctionen
dc.typeArtigo
dcterms.rightsHolderPerkin-elmer Corp

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções