dc.date.issued2012-11-01
dc.description.abstractThe aim of this study was to analyze the color alterations performed by the CIE L*a*b* system in the digital imaging of shade guide tabs, which were obtained photographically according to the automatic and manual modes. This study also sought to examine the observers' agreement in quantifying the coordinates. Four Vita Lumin Vaccum shade guide tabs were used: A3.5, B1, B3 and C4. An EOS Canon digital camera was used to record the digital images of the shade tabs, and the images were processed using Adobe Photoshop software. A total of 80 observations (five replicates of each shade according to two observers in two modes, specifically, automatic and manual) were obtained, leading to color values of L*, a* and b*. The color difference (AE) between the modes was calculated and classified as either clinically acceptable or unacceptable. The results indicated that there was agreement between the two observers in obtaining the L*, a* and b* values related to all guides. However, the B1, B3, and C4 shade tabs had AE values classified as clinically acceptable (Delta E = 0.44, Delta E = 2.04 and Delta E = 2.69, respectively). The A3.5 shade tab had a AE value classified as clinically unacceptable (Delta E = 4.17), as it presented higher values for luminosity in the automatic mode (L* = 54.0) than in the manual mode (L* = 50.6). It was concluded that the B1, B3 and C4 shade tabs can be used at any of the modes in digital camera (manual or automatic), which was a different finding from that observed for the A3.5 shade tab.en
dc.description.affiliationUniv Paulista Julio de Mesquita Filho UNESP, Dept Restorat Dent, Araraquara Dent Sch, Araraquara, SP, Brazil
dc.description.affiliationUniv Taubate UNITAU, Dept Clin Res Periodontol, Taubate, SP, Brazil
dc.description.affiliationUniv Paulista Julio de Mesquita Filho UNESP, Dept Social Dent, Araraquara Dent Sch, Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Paulista Julio de Mesquita Filho UNESP, Dept Restorat Dent, Araraquara Dent Sch, Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Paulista Julio de Mesquita Filho UNESP, Dept Social Dent, Araraquara Dent Sch, Araraquara, SP, Brazil
dc.format.extent578-583
dc.identifierhttp://dx.doi.org/10.1590/S1806-83242012005000025
dc.identifier.citationBrazilian Oral Research. São Paulo: Sociedade Brasileira de Pesquisa Odontologica, v. 26, n. 6, p. 578-583, 2012.
dc.identifier.fileS1806-83242012000600015.pdf
dc.identifier.issn1806-8324
dc.identifier.lattes2897622509429759
dc.identifier.lattes3085271271577719
dc.identifier.scieloS1806-83242012000600015
dc.identifier.urihttp://hdl.handle.net/11449/16695
dc.identifier.wosWOS:000311660600015
dc.language.isoeng
dc.publisherSociedade Brasileira de Pesquisa Odontológica (SBPqO)
dc.relation.ispartofBrazilian Oral Research
dc.rights.accessRightsAcesso abertopt
dc.sourceWeb of Science
dc.subjectToothen
dc.subjectColor Perceptionen
dc.subjectImage Processing, Computer-Assisteden
dc.titleCIE L*a*b*: comparison of digital images obtained photographically by manual and automatic modesen
dc.typeArtigopt
dcterms.licensehttp://www.scielo.br/revistas/bor/paboutj.htm
dcterms.rightsHolderSociedade Brasileira de Pesquisa Odontologica
dspace.entity.typePublication
relation.isDepartmentOfPublication63be3ea1-ddb8-4e20-b4ba-b2c3a2421a32
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery63be3ea1-ddb8-4e20-b4ba-b2c3a2421a32
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes2897622509429759
unesp.author.lattes3085271271577719
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt
unesp.departmentOdontologia Social - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1806-83242012000600015.pdf
Tamanho:
146.6 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: