Publicação:
Influence of different routes of flush perfusion on the distribution of lung preservation solutions in parenchyma and airways

dc.contributor.authorBitu-Moreno, José
dc.contributor.authorFrancischetti, Ieda
dc.contributor.authorSiemer, Ralph
dc.contributor.authorMatheis, Georg
dc.contributor.authorBaretti, Rufus
dc.contributor.authorMaffei, Francisco Humberto de Abreu [UNESP]
dc.contributor.authorKreitmayr, Barbara
dc.contributor.authorBeyersdorf, Friedhelm
dc.contributor.institutionAlbert-Ludwigs-University Freiburg
dc.contributor.institutionJohann Wolfgang Goethe-Univ. F.
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:19:43Z
dc.date.available2014-05-27T11:19:43Z
dc.date.issued1999-04-01
dc.description.abstractObjective: The present study was performed to investigate the influence of different routes of perfusion on the distribution of the preservation solutions in the lung parenchyma and upper airways. Methods: Pigs were divided into four groups: control (n = 6), pulmonary artery (PA) (n = 6), simultaneous PA + bronchial artery (BA) (n = 8), and retrograde delivery (n = 6). After preparation and cannulation, cardioplegia solution and Euro- Collins solution (ECS) for lung preservation were given simultaneously. After removal of the heart, the double lung bloc was harvested. Following parameters were assessed: total and regional perfusion (dye-labeled microspheres), tissue water content, PA, aorta, left atrial and left ventricular pressures, cardiac output and lung temperature. Results: Our data show that flow of the ECS in lung parenchyma did not reach control values (9.4 ± 1.0 ml/min per g lung wet weight) regardless of the route of delivery (PA 6.3 ± 1.5, PA + BA 4.8 ± 0.9, retrograde 2.7 ± 0.9 ml/min per g lung wet weight). However, flow in the proximal and distal trachea were significantly increased by PA + BA delivery (0.970 ± 0.4, respectively, 0.380 ± 0.2 ml/min per g) in comparison with PA (0.023 ± 0.007, respectively, 0.024 ± 0.070 ml/min per g), retrograde (0.009 ± 0.003, respectively, 0.021 ± 0.006 ml/min per g) and control experiments (0.125 ± 0.0018, respectively, 0.105 ± 0.012 ml/g per min). Similarly the highest flow rates in the right main bronchus were achieved by PA + BA delivery (1.04 ± 0.4 ml/min per g) in comparison with 0.11 ± 0.03 in control, 0.033 ± 0.008 in PA, and 0.019 ± 0.005 ml/min per g in retrograde group. Flows in the left main bronchus were 0.09 ± 0.02 ml/min per g in control, 0.045 ± 0.012 ml/min per g in PA, and 0.027 ± 0.006 ml/min per g in retrograde group. The flow rates were significantly (P = 0.001) increased by PA + BA delivery of the storage solution (0.97 ± 0.3 ml/min per g). Conclusions: Our data show that the distribution of ECS for lung preservation is significantly improved in airway tissues (trachea and bronchi) if a simultaneous PA + BA delivery is used.en
dc.description.affiliationDepartment of Cardiovascular Surgery Albert-Ludwigs-University Freiburg, Freiburg
dc.description.affiliationDept. Thorac. and Cardiovasc. Surg. Johann Wolfgang Goethe-Univ. F., Frankfurt
dc.description.affiliationFaculdade Med. Marilia Faculdade M. State University of Sao Paulo, Sao Paulo
dc.format.extent481-489
dc.identifierhttp://dx.doi.org/10.1016/S1010-7940(99)00050-0
dc.identifier.citationEuropean Journal of Cardio-thoracic Surgery, v. 15, n. 4, p. 481-489, 1999.
dc.identifier.doi10.1016/S1010-7940(99)00050-0
dc.identifier.issn1010-7940
dc.identifier.scopus2-s2.0-0032923262
dc.identifier.urihttp://hdl.handle.net/11449/65747
dc.language.isoeng
dc.relation.ispartofEuropean Journal of Cardio-thoracic Surgery
dc.relation.ispartofjcr3.504
dc.relation.ispartofsjr1,681
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectLung preservation
dc.subjectLung transplantation
dc.subjectPulmonary + bronchial perfusion
dc.subjectcardioplegic agent
dc.subjectEuro Collins solution
dc.subjectaorta pressure
dc.subjectbronchus
dc.subjectcontrolled study
dc.subjectflow rate
dc.subjectheart left atrium pressure
dc.subjectheart left ventricle pressure
dc.subjectheart output
dc.subjectlung artery pressure
dc.subjectlung parenchyma
dc.subjectlung perfusion
dc.subjectlung transplantation
dc.subjectnonhuman
dc.subjectpriority journal
dc.subjectswine
dc.subjecttissue preservation
dc.subjecttissue water
dc.subjecttrachea
dc.subjectAnimals
dc.subjectBronchi
dc.subjectHypertonic Solutions
dc.subjectLung
dc.subjectMale
dc.subjectOrgan Preservation Solutions
dc.subjectRegional Blood Flow
dc.subjectRespiratory System
dc.subjectSwine
dc.subjectTissue Distribution
dc.subjectTrachea
dc.titleInfluence of different routes of flush perfusion on the distribution of lung preservation solutions in parenchyma and airwaysen
dc.typeArtigo
dcterms.licensehttp://www.oxfordjournals.org/access_purchase/self-archiving_policyb.html
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentCirurgia e Ortopedia - FMBpt

Arquivos