Logotipo do repositório
 

Publicação:
Influence of powder-liquid ratio on the physicochemical properties of MTA Repair HP cement

dc.contributor.authorBosso-Martelo, Roberta
dc.contributor.authorPivoto-João, Mariana Mena Barreto [UNESP]
dc.contributor.authorZordan-Bronzel, Cristiane Lopes [UNESP]
dc.contributor.authorViola, Kennia Scapin [UNESP]
dc.contributor.authorCoaguila-Llerena, Hernán [UNESP]
dc.contributor.authorTanomaru-Filho, Mario [UNESP]
dc.contributor.institutionUniversidade Federal da Bahia (UFBA)
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-29T08:27:58Z
dc.date.available2022-04-29T08:27:58Z
dc.date.issued2018-01-01
dc.description.abstractIntroduction: MTA Repair HP has been recently developed. The aim of this study was to evaluate setting time, radiopacity and solubility of HP Repair MTA in powder-liquid ratio according to manufacturer's instructions (MTA HP+, 0.8 g powder and liquid 320μl) or less powder (MTA HP- 0.7 g powder and liquid 320 μl) compared to MTA Angelus. Material and methods: The radiopacity was assessed by radiographs of materials in relation to an aluminum scale. Setting time was evaluated by Gilmore needles; and solubility, after immersing the material in distilled water (7 days). Data were analyzed by using ANOVA and Tukey tests with a 5% significance level. Results: The initial and final setting times were longer for MTA HP- than MTA HP+ and MTA Angelus (p < 0.05). MTA HP+ and MTA HP- had higher solubility than the MTA Angelus (p < 0.05). The radiopacity values of MTA HP+ and MTA HP- were lower than the MTA Angelus (p < 0.05). Conclusions: Decreasing the amount of powder in powder-liquid ratio of MTA HP results in longer setting time, with no change in other properties evaluated. MTA HP had lower radiopacity than MTA Angelus.en
dc.description.affiliationUniversidade Federal da Bahia Curso de Odontologia
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Odontologia de Araraquara Departamento de Odontologia Restauradora
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Odontologia de Araraquara Departamento de Odontologia Restauradora
dc.format.extent46-50
dc.identifierhttp://dx.doi.org/10.14436/2358-2545.8.1.046-050.oar
dc.identifier.citationDental Press Endodontics, v. 8, n. 1, p. 46-50, 2018.
dc.identifier.doi10.14436/2358-2545.8.1.046-050.oar
dc.identifier.issn2178-3713
dc.identifier.scopus2-s2.0-85062938320
dc.identifier.urihttp://hdl.handle.net/11449/228668
dc.language.isoeng
dc.relation.ispartofDental Press Endodontics
dc.sourceScopus
dc.subjectDental Pulp Cavity
dc.subjectEndodontics
dc.subjectRoot Canal Preparation
dc.titleInfluence of powder-liquid ratio on the physicochemical properties of MTA Repair HP cementen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos