Quantification of a COVID-19 Antibody Assay Using a Lateral Flow Test and a Cell Phone
dc.contributor.author | Thompson, Pearl | |
dc.contributor.author | Bovolato, Ana Lívia de Carvalho [UNESP] | |
dc.contributor.author | Ibáñez-Redín, Gisela | |
dc.contributor.author | Brolo, Alexandre G. | |
dc.contributor.institution | University of Victoria | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2023-03-01T20:13:52Z | |
dc.date.available | 2023-03-01T20:13:52Z | |
dc.date.issued | 2022-07-01 | |
dc.description.abstract | Although several biomedical assays have been developed to screen for antibodies against SARS-CoV-2, very few can be completed without drawing blood. We developed a rapid lateral flow screening tool that used saliva samples and yielded rapid results that could be quantified using a cell phone. This assay provided the sensitive detection of IgG antibodies against SARS-CoV-2 within 10 min. We started by synthesising, modifying, and characterising gold nanoparticles. Using these particles as a coloured label, we developed a lateral flow strip made of nitrocellulose, glass fibre, and cellulose material. We quantified our visual results using pictures acquired with a cell phone and calculated a limit of detection of 4 ng/mL of antibodies against the SARS-CoV-2 spike protein. | en |
dc.description.affiliation | Department of Chemistry University of Victoria | |
dc.description.affiliation | Institute of Biosciences São Paulo State University—UNESP | |
dc.description.affiliation | Sao Carlos Institute of Physics University of São Paulo—USP | |
dc.description.affiliation | Centre for Advanced Materials and Related Technologies (CAMTEC) University of Victoria | |
dc.description.affiliationUnesp | Institute of Biosciences São Paulo State University—UNESP | |
dc.description.sponsorship | Natural Sciences and Engineering Research Council of Canada | |
dc.description.sponsorship | University of Victoria | |
dc.identifier | http://dx.doi.org/10.3390/chemosensors10070234 | |
dc.identifier.citation | Chemosensors, v. 10, n. 7, 2022. | |
dc.identifier.doi | 10.3390/chemosensors10070234 | |
dc.identifier.issn | 2227-9040 | |
dc.identifier.scopus | 2-s2.0-85133169547 | |
dc.identifier.uri | http://hdl.handle.net/11449/240364 | |
dc.language.iso | eng | |
dc.relation.ispartof | Chemosensors | |
dc.source | Scopus | |
dc.subject | COVID-19 | |
dc.subject | gold nanoparticles | |
dc.subject | IgG | |
dc.subject | lateral flow | |
dc.subject | saliva | |
dc.subject | SARS-CoV-2 | |
dc.title | Quantification of a COVID-19 Antibody Assay Using a Lateral Flow Test and a Cell Phone | en |
dc.type | Artigo | |
dspace.entity.type | Publication |