Logo do repositório
 

Comparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distribution

dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorRicardo Barao, Valentim Adelino [UNESP]
dc.contributor.authorTabata, Lucas Fernando [UNESP]
dc.contributor.authorSousa, Edson Antonio Capello [UNESP]
dc.contributor.authorGomes, Erica Alves [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:10:35Z
dc.date.accessioned2014-05-20T13:43:32Z
dc.date.available2013-09-30T18:10:35Z
dc.date.available2014-05-20T13:43:32Z
dc.date.issued2009-12-01
dc.description.abstractComparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distributionBackground:The effect of different mucosa characteristics on stress distribution of complete dentures and overdentures remains unknown.Objective:The aim of this study was to evaluate the effect of different mucosa thickness and resiliency on the stress distribution of complete dentures and implant-retained overdentures using a two-dimensional finite element analysis.Material and methods:Representative models of the edentulous mandible were constructed on AutoCAD software according to the groups' characteristics. In group CD, a model of the edentulous mandible supporting a complete denture was obtained while in group IO, a model of edentulous mandible supporting an overdenture over two unsplinted implants with an o' ring system was constructed. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) corresponding to the resiliencies hard, resilient and soft respectively. Evaluation was performed on Ansys software with 100N vertical load applied on central incisor teeth. The principal stress was used as analysis criteria.Results:Group IO showed higher stress values than group CD regardless of mucosal thickness and resiliency. Stress decreased at the supporting tissues in both groups as the thickness and resiliency of mucosa increased. In relation to the supporting tissues, cortical bone showed the highest stress values.Conclusion:It was concluded that the use of an attachment system increases stress values and the thickness and resiliency of mucosa influence more on these values.en
dc.description.affiliationSão Paulo State Univ, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, UNESP, BR-16015050 Aracatuba, SP, Brazil
dc.description.affiliationSão Paulo State Univ, Bauru Engn Sch, Dept Mech Engn, UNESP, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, UNESP, BR-16015050 Aracatuba, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Bauru Engn Sch, Dept Mech Engn, UNESP, São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 06/52230-6
dc.description.sponsorshipIdFAPESP: 06/59770-6
dc.format.extent273-281
dc.identifierhttp://dx.doi.org/10.1111/j.1741-2358.2008.00268.x
dc.identifier.citationGerodontology. Malden: Wiley-blackwell Publishing, Inc, v. 26, n. 4, p. 273-281, 2009.
dc.identifier.doi10.1111/j.1741-2358.2008.00268.x
dc.identifier.issn0734-0664
dc.identifier.lattes4438747643373395
dc.identifier.urihttp://hdl.handle.net/11449/15201
dc.identifier.wosWOS:000271940300006
dc.language.isoeng
dc.publisherWiley-Blackwell Publishing, Inc
dc.relation.ispartofGerodontology
dc.relation.ispartofjcr1.439
dc.relation.ispartofsjr0,627
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectdental implantsen
dc.subjectcomplete dentureen
dc.subjectoverdentureen
dc.subjectattachmenten
dc.subjectfinite element analysisen
dc.subjectbiomechanicsen
dc.titleComparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distributionen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell Publishing, Inc
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes8934648262859482
unesp.author.orcid0000-0002-8903-0737[1]
unesp.author.orcid0000-0002-6510-3727[6]
unesp.author.orcid0000-0002-6391-9917[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Baurupt
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentEngenharia Mecânica - FEBpt

Arquivos

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: