Comparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distribution
dc.contributor.author | Assunção, Wirley Goncalves [UNESP] | |
dc.contributor.author | Ricardo Barao, Valentim Adelino [UNESP] | |
dc.contributor.author | Tabata, Lucas Fernando [UNESP] | |
dc.contributor.author | Sousa, Edson Antonio Capello [UNESP] | |
dc.contributor.author | Gomes, Erica Alves [UNESP] | |
dc.contributor.author | Delben, Juliana Aparecida [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2013-09-30T18:10:35Z | |
dc.date.accessioned | 2014-05-20T13:43:32Z | |
dc.date.available | 2013-09-30T18:10:35Z | |
dc.date.available | 2014-05-20T13:43:32Z | |
dc.date.issued | 2009-12-01 | |
dc.description.abstract | Comparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distributionBackground:The effect of different mucosa characteristics on stress distribution of complete dentures and overdentures remains unknown.Objective:The aim of this study was to evaluate the effect of different mucosa thickness and resiliency on the stress distribution of complete dentures and implant-retained overdentures using a two-dimensional finite element analysis.Material and methods:Representative models of the edentulous mandible were constructed on AutoCAD software according to the groups' characteristics. In group CD, a model of the edentulous mandible supporting a complete denture was obtained while in group IO, a model of edentulous mandible supporting an overdenture over two unsplinted implants with an o' ring system was constructed. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) corresponding to the resiliencies hard, resilient and soft respectively. Evaluation was performed on Ansys software with 100N vertical load applied on central incisor teeth. The principal stress was used as analysis criteria.Results:Group IO showed higher stress values than group CD regardless of mucosal thickness and resiliency. Stress decreased at the supporting tissues in both groups as the thickness and resiliency of mucosa increased. In relation to the supporting tissues, cortical bone showed the highest stress values.Conclusion:It was concluded that the use of an attachment system increases stress values and the thickness and resiliency of mucosa influence more on these values. | en |
dc.description.affiliation | São Paulo State Univ, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, UNESP, BR-16015050 Aracatuba, SP, Brazil | |
dc.description.affiliation | São Paulo State Univ, Bauru Engn Sch, Dept Mech Engn, UNESP, São Paulo, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, UNESP, BR-16015050 Aracatuba, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, Bauru Engn Sch, Dept Mech Engn, UNESP, São Paulo, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 06/52230-6 | |
dc.description.sponsorshipId | FAPESP: 06/59770-6 | |
dc.format.extent | 273-281 | |
dc.identifier | http://dx.doi.org/10.1111/j.1741-2358.2008.00268.x | |
dc.identifier.citation | Gerodontology. Malden: Wiley-blackwell Publishing, Inc, v. 26, n. 4, p. 273-281, 2009. | |
dc.identifier.doi | 10.1111/j.1741-2358.2008.00268.x | |
dc.identifier.issn | 0734-0664 | |
dc.identifier.lattes | 4438747643373395 | |
dc.identifier.uri | http://hdl.handle.net/11449/15201 | |
dc.identifier.wos | WOS:000271940300006 | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell Publishing, Inc | |
dc.relation.ispartof | Gerodontology | |
dc.relation.ispartofjcr | 1.439 | |
dc.relation.ispartofsjr | 0,627 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Web of Science | |
dc.subject | dental implants | en |
dc.subject | complete denture | en |
dc.subject | overdenture | en |
dc.subject | attachment | en |
dc.subject | finite element analysis | en |
dc.subject | biomechanics | en |
dc.title | Comparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distribution | en |
dc.type | Artigo | pt |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dcterms.rightsHolder | Wiley-blackwell Publishing, Inc | |
dspace.entity.type | Publication | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 8934648262859482 | |
unesp.author.orcid | 0000-0002-8903-0737[1] | |
unesp.author.orcid | 0000-0002-6510-3727[6] | |
unesp.author.orcid | 0000-0002-6391-9917[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Engenharia, Bauru | pt |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Engenharia Mecânica - FEB | pt |
Arquivos
Licença do pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: