Logo do repositório
 

Cutting Ability of Nickel-titanium rotary systems protaper, mtwo and k3

dc.contributor.authorMoraes, Sergio Herrero [UNESP]
dc.contributor.authorGonçalves, Marcelo [UNESP]
dc.contributor.authorTanomaru Filho, Mário [UNESP]
dc.contributor.authorBonetti Filho, Idomeo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-08-06T16:12:39Z
dc.date.available2015-08-06T16:12:39Z
dc.date.issued2012
dc.description.abstractNickel-titanium rotatory systems should remove dentin during the root canal preparation to promote the enlargement and tapered shape with continuously narrowing towards the apex. Objective: The aim of this study was to analyze the cutting ability of three NiTi rotatory systems (n = 12): ProTaper (group 1), Mtwo (group 2), and K3 (group 3). Material and methods: Thirty six maxillary molar teeth were weighted on an analytical balance before and after the rotatory preparation of the mesio-buccal root canal. Data was statistically analyzed by ANOVA and Tukey s test with a significance level of 5%. Results: The results revealed the following mass differences (g) before and after the root canal preparation: ProTaper (group 1 – 0.0159 ± 0.004), Mtwo (group 2 – 0.0125 ± 0.002), and K3 (group 3 – 0.007 ± 0.003). Conclusion: ProTaper showed the highest cutting ability among the three tested nickel-titanium rotatory systems followed by Mtwo and K3.en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Diagnóstico e Cirurgia, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680, Centro, CEP 14801-903, SP, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Diagnóstico e Cirurgia, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680, Centro, CEP 14801-903, SP, Brasil
dc.format.extent177-182
dc.identifierhttp://revodonto.bvsalud.org/scielo.php?script=sci_arttext&pid=S1984-56852012000200010&lng=pt&nrm=iso&tlng=en
dc.identifier.citationRSBO. Revista Sul-Brasileira de Odontologia, v. 9, n. 2, p. 177-182, 2012.
dc.identifier.issn1806-7727
dc.identifier.lattes1067437159861527
dc.identifier.lattes2665211298584751
dc.identifier.lattes5309258790184438
dc.identifier.urihttp://hdl.handle.net/11449/125626
dc.language.isoeng
dc.relation.ispartofRSBO. Revista Sul-Brasileira de Odontologia
dc.rights.accessRightsAcesso abertopt
dc.sourceCurrículo Lattes
dc.subjectEndodonticsen
dc.subjectInstrumentsen
dc.subjectRoot canal preparationen
dc.titleCutting Ability of Nickel-titanium rotary systems protaper, mtwo and k3en
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes1067437159861527
unesp.author.lattes2665211298584751
unesp.author.lattes5309258790184438
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos