Logotipo do repositório
 

Publicação:
Effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures-2D FEA

dc.contributor.authorRicardo Barao, Valentim Adelino [UNESP]
dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorTabata, Lucas Fernando [UNESP]
dc.contributor.authorSousa, Edson Antonio Capello [UNESP]
dc.contributor.authorRocha, Eduardo Passos [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:10:32Z
dc.date.accessioned2014-05-20T13:43:33Z
dc.date.available2013-09-30T18:10:32Z
dc.date.available2014-05-20T13:43:33Z
dc.date.issued2008-11-01
dc.description.abstractThe study aimed to evaluate the effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures using a two-dimensional finite element analysis. Models were used in order to simulate two situations. In group A, model represented an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system while in group B, model simulated an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system associated with two-distally placed o'ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) in the resiliencies: hard, resilient and soft, respectively Evaluation was performed on Ansys software. Group A showed higher stress values regardless of the mucosa characteristics. Overall, stress decreased at the supporting tissues as mucosa. thickness and resiliency increased. Regarding supporting tissues, cortical bone showed the highest stress values. The use of bar-clip attachment system with distally placed o'ring attachment design optimized the stress distribution. (C) 2008 Elsevier B.V. All rights reserved.en
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 06/52230-6
dc.description.sponsorshipIdFAPESP: 06/59770-6
dc.format.extent213-223
dc.identifierhttp://dx.doi.org/10.1016/j.cmpb.2008.07.009
dc.identifier.citationComputer Methods and Programs In Biomedicine. Clare: Elsevier B.V., v. 92, n. 2, p. 213-223, 2008.
dc.identifier.doi10.1016/j.cmpb.2008.07.009
dc.identifier.issn0169-2607
dc.identifier.lattes4438747643373395
dc.identifier.lattes3383392287039820
dc.identifier.urihttp://hdl.handle.net/11449/15204
dc.identifier.wosWOS:000260919300007
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofComputer Methods and Programs In Biomedicine
dc.relation.ispartofjcr2.674
dc.relation.ispartofsjr0,786
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectDental implantsen
dc.subjectOverdentureen
dc.subjectAttachmenten
dc.subjectFinite element analysisen
dc.subjectBiomechanicsen
dc.titleEffect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures-2D FEAen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes8934648262859482
unesp.author.orcid0000-0002-8903-0737[2]
unesp.author.orcid0000-0002-6391-9917[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Baurupt
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentEngenharia Mecânica - FEBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: