Publicação: Effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures-2D FEA
Carregando...
Data
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Elsevier B.V.
Tipo
Artigo
Direito de acesso
Acesso restrito
Resumo
The study aimed to evaluate the effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures using a two-dimensional finite element analysis. Models were used in order to simulate two situations. In group A, model represented an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system while in group B, model simulated an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system associated with two-distally placed o'ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) in the resiliencies: hard, resilient and soft, respectively Evaluation was performed on Ansys software. Group A showed higher stress values regardless of the mucosa characteristics. Overall, stress decreased at the supporting tissues as mucosa. thickness and resiliency increased. Regarding supporting tissues, cortical bone showed the highest stress values. The use of bar-clip attachment system with distally placed o'ring attachment design optimized the stress distribution. (C) 2008 Elsevier B.V. All rights reserved.
Descrição
Palavras-chave
Dental implants, Overdenture, Attachment, Finite element analysis, Biomechanics
Idioma
Inglês
Como citar
Computer Methods and Programs In Biomedicine. Clare: Elsevier B.V., v. 92, n. 2, p. 213-223, 2008.