Publicação:
Agreement between direct, oscillometric and Doppler ultrasound blood pressures using three different cuff positions in anesthetized dogs

dc.contributor.authorGarofalo, Natache A. [UNESP]
dc.contributor.authorTeixeira Neto, Francisco José [UNESP]
dc.contributor.authorAlvaides, Renata K. [UNESP]
dc.contributor.authorde Oliveira, Flavia A. [UNESP]
dc.contributor.authorPignaton, Wangles [UNESP]
dc.contributor.authorPinheiro, Renato T. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:33:14Z
dc.date.available2014-05-20T15:33:14Z
dc.date.issued2012-07-01
dc.description.abstractObjective To evaluate the agreement between invasive blood pressure (IBP) and Doppler ultrasound blood pressure (DUBP) using three cuff positions and oscillometric blood pressure (OBP) in anesthetized dogs.Study design Prospective study. Animals Nine adult dogs weighing 14.5-29.5 kg.Methods The cuff was placed above and below the tarsus, and above the carpus with the DUBP and above the carpus with the OBP monitor. Based on IBP recorded via a dorsal pedal artery catheter, conditions of low, normal, and high systolic arterial pressures [SAP (mmHg) <90, between 90 and 140, and >140, respectively] were induced by changes in isoflurane concentrations and/or dopamine administration. Mean biases +/- 2 SD (limits of agreement) were determined.Results At high blood pressures, regardless of cuff position, SAP determinations with the DUBP under-estimated invasive SAP values by more than 20 mmHg in most instances. With the DUBP, cuff placement above the tarsus yielded better agreement with invasive SAP during low blood pressures (0.2 +/- 16 mmHg). The OBP underestimated SAP during high blood pressures (-42 +/- 42 mmHg) and yielded better agreement with IBP for mean (MAP) and diastolic (DAP) arterial pressure measurements [overall bias: 2 +/- 15 mmHg (MAP) and 0.2 +/- 16 mmHg (DAP)].Conclusions Agreement of SAP determinations with the DUBP is poor at SAP > 140 mmHg, regardless of cuff placement. Measurement error of the DUBP with the cuff placed above the tarsus is clinically acceptable during low blood pressures. Agreement of MAP and DAP measurements with this OBP monitor compared with IBP was clinically acceptable over a wide pressure range.Clinical relevance With the DUBP device, placing the cuff above the tarsus allows reasonable agreement with IBP obtained via dorsal pedal artery catheterization. Only MAP and DAP provide reasonable estimates of direct blood pressure with the OBP monitor evaluated.en
dc.description.affiliationUniv Estadual Paulista, Fac Med Vet & Zootecnia, Dept Cirurgia & Anestesiol Vet, BR-18618970 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Fac Med Vet & Zootecnia, Dept Cirurgia & Anestesiol Vet, BR-18618970 São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 06/52900-1
dc.format.extent324-334
dc.identifierhttp://dx.doi.org/10.1111/j.1467-2995.2012.00711.x
dc.identifier.citationVeterinary Anaesthesia and Analgesia. Hoboken: Wiley-blackwell, v. 39, n. 4, p. 324-334, 2012.
dc.identifier.doi10.1111/j.1467-2995.2012.00711.x
dc.identifier.issn1467-2987
dc.identifier.urihttp://hdl.handle.net/11449/41918
dc.identifier.wosWOS:000305514100003
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofVeterinary Anaesthesia and Analgesia
dc.relation.ispartofjcr2.064
dc.relation.ispartofsjr0,800
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectarterial blood pressureen
dc.subjectdogsen
dc.subjectdoppleren
dc.subjectnon-invasive blood pressureen
dc.subjectoscillometryen
dc.titleAgreement between direct, oscillometric and Doppler ultrasound blood pressures using three different cuff positions in anesthetized dogsen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
unesp.author.orcid0000-0002-3002-8093[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária e Zootecnia, Botucatupt
unesp.departmentCirurgia e Anestesiologia Veterinária - FMVZpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: