Logo do repositório

Development and mechanical properties of a locking T-plate

dc.contributor.authorMesquita, Luciane R. [UNESP]
dc.contributor.authorRahal, Sheila C. [UNESP]
dc.contributor.authorNeto, Camilo Mesquita
dc.contributor.authorKano, Washington T. [UNESP]
dc.contributor.authorBeato, Antônio C.
dc.contributor.authorFaria, Luís G. [UNESP]
dc.contributor.authorCastilho, Maíra S. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionIPAC
dc.date.accessioned2018-12-11T17:14:27Z
dc.date.available2018-12-11T17:14:27Z
dc.date.issued2017-05-01
dc.description.abstractThis study aimed to develop a locking T-plate and to evaluate its mechanical properties in synthetic models. A titanium 2.7mm T-plate was designed with a shaft containing three locked screw holes and one dynamic compression hole, and a head with two locked screw holes. Forty T-shaped polyurethane blocks, and 20 T-plates were used for mechanical testing. Six bone-plate constructs were tested to failure, three in axial compression and three in cantilever bending. Fourteen bone-plate constructs were tested for failure in fatigue, seven in axial compression and seven in cantilever bending. In static testing higher values of axial compression test than cantilever bending test were observed for all variables. In axial compression fatigue testing all bone-plate constructs withstood 1,000,000 cycles. Four bone- plate constructs failure occurred before 1,000,000 cycles in cantilever bending fatigue testing. In conclusion, the locking T-plate tested has mechanical properties that offer greatest resistance to fracture under axial loading than bending forces.en
dc.description.affiliationDepartment of Veterinary Surgery and Anesthesiology School of Veterinary Medicine and Animal Science Universidade Estadual Paulista (Unesp), Cx. Postal 560, Rubião Júnior s/n
dc.description.affiliationLaboratório de Ensaios Mecânicos e Metalográficos (LEMM) IPAC, Rua Luiz Pengo 145
dc.description.affiliationUnespDepartment of Veterinary Surgery and Anesthesiology School of Veterinary Medicine and Animal Science Universidade Estadual Paulista (Unesp), Cx. Postal 560, Rubião Júnior s/n
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.format.extent495-501
dc.identifierhttp://dx.doi.org/10.1590/S0100-736X2017000500012
dc.identifier.citationPesquisa Veterinaria Brasileira, v. 37, n. 5, p. 495-501, 2017.
dc.identifier.doi10.1590/S0100-736X2017000500012
dc.identifier.fileS0100-736X2017000500495.pdf
dc.identifier.issn1678-5150
dc.identifier.issn0100-736X
dc.identifier.scieloS0100-736X2017000500495
dc.identifier.scopus2-s2.0-85028611548
dc.identifier.urihttp://hdl.handle.net/11449/175116
dc.language.isoeng
dc.relation.ispartofPesquisa Veterinaria Brasileira
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectBone-plate
dc.subjectFracture
dc.subjectImplant
dc.subjectMechanical study
dc.titleDevelopment and mechanical properties of a locking T-plateen
dc.typeArtigo
dspace.entity.typePublication
relation.isOrgUnitOfPublication9ca5a87b-0c83-43fa-b290-6f8a4202bf99
relation.isOrgUnitOfPublication.latestForDiscovery9ca5a87b-0c83-43fa-b290-6f8a4202bf99
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária e Zootecnia, Botucatupt
unesp.departmentCirurgia e Anestesiologia Veterinária - FMVZpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0100-736X2017000500495.pdf
Tamanho:
2.48 MB
Formato:
Adobe Portable Document Format