Logotipo do repositório
 

Publicação:
Biological Performance of Chemical Hydroxyapatite Coating Associated With Implant Surface Modification by Laser Beam: Biomechanical Study in Rabbit Tibias

dc.contributor.authorFaeda, Rafael S. [UNESP]
dc.contributor.authorTavares, Hewerson S. [UNESP]
dc.contributor.authorSartori, Rafael
dc.contributor.authorGuastaldi, Antonio C. [UNESP]
dc.contributor.authorMarcantonio, Elcio
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:31:56Z
dc.date.accessioned2014-05-20T13:45:28Z
dc.date.available2013-09-30T18:31:56Z
dc.date.available2014-05-20T13:45:28Z
dc.date.issued2009-08-01
dc.description.abstractPurpose: Considering the potential of the association between laser ablation and smaller scale hydroxyapatite (HA) coatings to create a stable and bioactive surface on titanium dental implants, the aim of the present study was to determine, by the removal torque test, the effects of a surface treatment created by laser-ablation (Nd:YAG) and, later, thin deposition of HA particles by a chemical process, compared to implants with only laser-ablation and implants with machined surfaces.Materials and Methods: Forty-eight rabbits received I implant by tibia of the following surfaces: machined surface (MS), laser-modified surface (LMS), and biomimetic hydroxiapatite coated surface (HA). After 4, 8, and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition, and roughness.Results: Average removal torque in each period was 23.28, 24.0, and 33.85 Ncm to MS, 33.0, 39.87, and 54.57 Ncm to LMS, and 55.42, 63.71 and 64.0 Ncm to HA. The difference was statistically significant (P < .05) between the LMS-MS and HA-MS surfaces in all periods of evaluation, and between LMS-HA to 4 and 8 weeks of healing. The surface characterization showed a deep, rough, and regular topography provided by the laser conditioning, that was followed by the HA coating.Conclusions: Based on these results, it was possible to conclude that the implants with laser surface modification associated with HA biomimetic coating can shorten the implant healing period by the increase of bone implant interaction during the first 2 months after implant placement. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:1706-1715, 2009en
dc.description.affiliationUNESP, Fac Odontol, Disciplina Periodontia, Dept Periodontol,Sch Dent, Araraquara, SP, Brazil
dc.description.affiliationUNESP, Dept Biomat, Inst Chem, Araraquara, SP, Brazil
dc.description.affiliationUnespUNESP, Fac Odontol, Disciplina Periodontia, Dept Periodontol,Sch Dent, Araraquara, SP, Brazil
dc.description.affiliationUnespUNESP, Dept Biomat, Inst Chem, Araraquara, SP, Brazil
dc.format.extent1706-1715
dc.identifierhttp://dx.doi.org/10.1016/j.joms.2009.03.046
dc.identifier.citationJournal of Oral and Maxillofacial Surgery. Philadelphia: W B Saunders Co-elsevier Inc, v. 67, n. 8, p. 1706-1715, 2009.
dc.identifier.doi10.1016/j.joms.2009.03.046
dc.identifier.issn0278-2391
dc.identifier.urihttp://hdl.handle.net/11449/15996
dc.identifier.wosWOS:000268776800021
dc.language.isoeng
dc.publisherW B Saunders Co-elsevier Inc
dc.relation.ispartofJournal of Oral and Maxillofacial Surgery
dc.relation.ispartofjcr1.779
dc.relation.ispartofsjr0,967
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleBiological Performance of Chemical Hydroxyapatite Coating Associated With Implant Surface Modification by Laser Beam: Biomechanical Study in Rabbit Tibiasen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderW B Saunders Co-elsevier Inc
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes6443430122330366[4]
unesp.author.orcid0000-0002-9660-4524[5]
unesp.author.orcid0000-0002-6433-3555[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: