Logotipo do repositório
 

Publicação:
EVALUATION OF THE INFLUENCE OF THE STANDARD FIRE RESISTANCE CALCULATION METHODS IN THE VERIFICATION OF CONCRETE WALL BUILDINGS

dc.contributor.authorMarques, T. V. N.
dc.contributor.authorSilva, T. D.
dc.contributor.authorMascarenhas, F. J. R.
dc.contributor.authorCanhada, J. C. dos S. [UNESP]
dc.contributor.authorChristoforo, A. L.
dc.contributor.authorCarvalho, R. C.
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-28T17:20:11Z
dc.date.available2022-04-28T17:20:11Z
dc.date.issued2021-01-01
dc.description.abstractIt is necessary, in order to carry out the assessment of concrete structures in a fire situation, to know the Standard Fire Resistance of the structural elements. Both the ABNT NBR 14432 (2001) and the ABNT NBR 15200 (2012) allow the determination of the Standard Fire Resistance by the Tabular Method or by the Equivalent Time Method. Even though both are accepted, it is commonly found in the technical and scientific field, discussions and applications of the Tabular Method, which frequently leads to higher figures of Standard Fire Resistance. The application of methods that lead to a lower Standard Fire Resistance is justified by the analysis of more economical structures, since the methods of verification of structures in fire conditions are based on these, to define the minimum dimensions of the structural elements. Therefore, the present research aimed to evaluate the influence of the application of the results of the two methods of Standard Fire Resistance determination in the verification of a multifamily residential building with concrete walls. Initially the Standard Fire Resistance was calculated by both methods and then, the building was verified according to the specifications of the ABNT NBR 15200 (2012). The usage of the Equivalent Time Method ensured a reduction of 12.5% in the concrete consumption, outlining the importance of its application.en
dc.description.affiliationUniv Fed Sao Carlos, Sao Carlos, SP, Brazil
dc.description.affiliationUniv Estadual Paulista, Sao Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Sao Paulo, Brazil
dc.format.extent15
dc.identifierhttp://dx.doi.org/10.15628/holos.2021.10412
dc.identifier.citationHolos. Rio Grande Do Norte: Centro Federal Educacao Tecnologica Rio Grande Norte, v. 37, n. 1, 15 p., 2021.
dc.identifier.doi10.15628/holos.2021.10412
dc.identifier.issn1518-1634
dc.identifier.urihttp://hdl.handle.net/11449/218269
dc.identifier.wosWOS:000661888400006
dc.language.isopor
dc.publisherCentro Federal Educacao Tecnologica Rio Grande Norte
dc.relation.ispartofHolos
dc.sourceWeb of Science
dc.subjectStructural Security
dc.subjectFire
dc.subjectConcrete Wall
dc.subjectStandard Fire Resistance
dc.titleEVALUATION OF THE INFLUENCE OF THE STANDARD FIRE RESISTANCE CALCULATION METHODS IN THE VERIFICATION OF CONCRETE WALL BUILDINGSen
dc.typeArtigo
dcterms.rightsHolderCentro Federal Educacao Tecnologica Rio Grande Norte