Publicação: The influence of cyclosporin a on mechanical retention of dental implants previously integrated to the bone: A study in rabbits
dc.contributor.author | Sakakura, Celso E. | |
dc.contributor.author | Margonar, Rogerio | |
dc.contributor.author | Sartori, Rafael | |
dc.contributor.author | Morais, Juliana A. N. D. | |
dc.contributor.author | Marcantonio, Elcio | |
dc.contributor.institution | Educ Fdn Barretos | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T15:23:14Z | |
dc.date.available | 2014-05-20T15:23:14Z | |
dc.date.issued | 2006-12-01 | |
dc.description.abstract | Background: Immunosuppressive agents may induce severe changes on bone metabolism and may impair the osseointegration process during the implant healing. No data are available concerning the influence of cyclosporin A on dental implants previously integrated to the bone. The aim of this study was to evaluate the influence of cyclosporin A administration on the mechanical retention of bone previously integrated to dental implants.Methods: Eighteen female New Zealand rabbits were submitted to an implant surgery. Each animal received one commercial dental implant of 10 x 3.75 mm. After 12 weeks of an undisturbed healing period, six animals were randomly sacrificed and the removal torque test was performed (group A). In addition, six animals were submitted to a daily injection of cyclosporin A in a dosage of 10 mg/kg (group C), and six animals received saline solution as a control (group B). After 12 weeks of cyclosporin A administration, groups B and C were sacrificed and submitted to a removal torque test in which higher values can be interpreted as higher mechanical bone retention to the implant surface or higher osseointegration.Results: the removal torque results were 30.5 (+/- 9.8) Ncm for group A, 50.17 (+/- 17.5) Ncm for group B, and 26 (+/- 7.8) Ncm for group C. The statistical analysis showed significant differences between groups A and B (P < 0.05) and groups B and C (P < 0.01).Conclusion: Cyclosporin A administration may impair the mechanical retention of dental implants previously integrated to the bone. | en |
dc.description.affiliation | Educ Fdn Barretos, Dept Periodontol, São Paulo, Brazil | |
dc.description.affiliation | State Univ São Paulo, Dent Sch Araraquara, Dept Periodontol, São Paulo, Brazil | |
dc.description.affiliationUnesp | State Univ São Paulo, Dent Sch Araraquara, Dept Periodontol, São Paulo, Brazil | |
dc.format.extent | 2059-2062 | |
dc.identifier | http://www.joponline.org/doi/abs/10.1902/jop.2006.050290 | |
dc.identifier.citation | Journal of Periodontology. Chicago: Amer Acad Periodontology, v. 77, n. 12, p. 2059-2062, 2006. | |
dc.identifier.doi | 10.1092/jop.2006.050290 | |
dc.identifier.issn | 0022-3492 | |
dc.identifier.uri | http://hdl.handle.net/11449/34067 | |
dc.identifier.wos | WOS:000243801300016 | |
dc.language.iso | eng | |
dc.publisher | Amer Acad Periodontology | |
dc.relation.ispartof | Journal of Periodontology | |
dc.relation.ispartofjcr | 3.392 | |
dc.relation.ispartofsjr | 1,408 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | cyclosporin A | pt |
dc.subject | dental implant | pt |
dc.subject | osseointegration | pt |
dc.subject | torque | pt |
dc.title | The influence of cyclosporin a on mechanical retention of dental implants previously integrated to the bone: A study in rabbits | en |
dc.type | Artigo | |
dcterms.license | http://www.joponline.org/userimages/ContentEditor/1124388816475/Instructions_to_Authors.pdf | |
dcterms.rightsHolder | Amer Acad Periodontology | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-9660-4524[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Diagnóstico e Cirurgia - FOAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: