Influence of Microwave Disinfection on the Linear Dimensional Stability of Complete Dentures: A Clinical Study
Loading...
External sources
External sources
Date
Advisor
Coadvisor
Graduate program
Undergraduate course
Journal Title
Journal ISSN
Volume Title
Publisher
Quintessence Publishing Co Inc
Type
Abstract
Access right
Acesso restrito
External sources
External sources
Abstract
This clinical study evaluated the effect of two microwave disinfection protocols at 650 W for 3 minutes (group 1, once a week; group 2, three times a week) on the linear dimensional stability of complete dentures. Measurements were taken across four reference points: before the first microwave disinfection (baseline) and after each week of disinfection. Furthermore, the dentures were monitored clinically. Group 2 showed significantly greater shrinkage than group 1 in all evaluated weeks. During clinical monitoring, no significant findings were observed. Even though dimensional changes occurred, the clinical evaluation did not yield any changes in either group. Int J Prosthodont 2010;23:318-320.