Logotipo do repositório
 

Publicação:
Influence of Microwave Disinfection on the Linear Dimensional Stability of Complete Dentures: A Clinical Study

Carregando...
Imagem de Miniatura

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Quintessence Publishing Co Inc

Tipo

Resumo

Direito de acesso

Acesso restrito

Resumo

This clinical study evaluated the effect of two microwave disinfection protocols at 650 W for 3 minutes (group 1, once a week; group 2, three times a week) on the linear dimensional stability of complete dentures. Measurements were taken across four reference points: before the first microwave disinfection (baseline) and after each week of disinfection. Furthermore, the dentures were monitored clinically. Group 2 showed significantly greater shrinkage than group 1 in all evaluated weeks. During clinical monitoring, no significant findings were observed. Even though dimensional changes occurred, the clinical evaluation did not yield any changes in either group. Int J Prosthodont 2010;23:318-320.

Descrição

Palavras-chave

Idioma

Inglês

Como citar

International Journal of Prosthodontics. Hanover Park: Quintessence Publishing Co Inc, v. 23, n. 4, p. 318-320, 2010.