Logotipo do repositório
 

Publicação:
Influence of Microwave Disinfection on the Linear Dimensional Stability of Complete Dentures: A Clinical Study

dc.contributor.authorManzolli Basso, Michael Frederico
dc.contributor.authorGiampaolo, Eunice Teresinha [UNESP]
dc.contributor.authorVergani, Carlos Eduardo [UNESP]
dc.contributor.authorMachado, Ana Lucia [UNESP]
dc.contributor.authorPavarina, Ana Claudia [UNESP]
dc.contributor.authorCompagnoni, Marco Antonio [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:46:37Z
dc.date.available2014-05-20T13:46:37Z
dc.date.issued2010-07-01
dc.description.abstractThis clinical study evaluated the effect of two microwave disinfection protocols at 650 W for 3 minutes (group 1, once a week; group 2, three times a week) on the linear dimensional stability of complete dentures. Measurements were taken across four reference points: before the first microwave disinfection (baseline) and after each week of disinfection. Furthermore, the dentures were monitored clinically. Group 2 showed significantly greater shrinkage than group 1 in all evaluated weeks. During clinical monitoring, no significant findings were observed. Even though dimensional changes occurred, the clinical evaluation did not yield any changes in either group. Int J Prosthodont 2010;23:318-320.en
dc.description.affiliationUniv Estadual Paulista, Dept Dent Mat & Prosthodont, Araraquara Dent Sch, UNESP, BR-14801903 Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Dent Mat & Prosthodont, Araraquara Dent Sch, UNESP, BR-14801903 Araraquara, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 05/04693-4
dc.format.extent318-320
dc.identifierhttp://www.ncbi.nlm.nih.gov/pubmed/20617219
dc.identifier.citationInternational Journal of Prosthodontics. Hanover Park: Quintessence Publishing Co Inc, v. 23, n. 4, p. 318-320, 2010.
dc.identifier.issn0893-2174
dc.identifier.lattes5737127334248549
dc.identifier.lattes3003130522427820
dc.identifier.lattes8000248781842587
dc.identifier.lattes8867670539105403
dc.identifier.lattes8921196002764597
dc.identifier.orcid0000-0002-7375-4714
dc.identifier.urihttp://hdl.handle.net/11449/16516
dc.identifier.wosWOS:000280182500005
dc.language.isoeng
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofInternational Journal of Prosthodontics
dc.relation.ispartofjcr1.333
dc.relation.ispartofsjr0,891
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleInfluence of Microwave Disinfection on the Linear Dimensional Stability of Complete Dentures: A Clinical Studyen
dc.typeResumopt
dcterms.licensehttp://www.uk.sagepub.com/aboutus/openaccess.htm
dcterms.rightsHolderQuintessence Publishing Co Inc
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes5737127334248549
unesp.author.lattes3003130522427820[3]
unesp.author.lattes8000248781842587[4]
unesp.author.lattes8867670539105403[5]
unesp.author.lattes8921196002764597
unesp.author.orcid0000-0002-9231-1994[5]
unesp.author.orcid0000-0001-8439-0816[6]
unesp.author.orcid0000-0002-2718-428X[4]
unesp.author.orcid0000-0002-7375-4714[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: