Logotipo do repositório
 

Publicação:
Are Zirconia Implant Abutments Safe and Predictable in Posterior Regions? A Systematic Review and Meta-Analysis

dc.contributor.authorJose Vechiato-Filho, Aljomar [UNESP]
dc.contributor.authorPesqueira, Aldieris Alves [UNESP]
dc.contributor.authorDe Souza, Grace M.
dc.contributor.authorSantos, Daniela Micheline dos [UNESP]
dc.contributor.authorPellizzer, Eduardo Piza [UNESP]
dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniv Toronto
dc.date.accessioned2018-11-26T16:33:03Z
dc.date.available2018-11-26T16:33:03Z
dc.date.issued2016-05-01
dc.description.abstractPurpose: This systematic review aimed to evaluate whether the survival rate and predictability of zirconia abutments are similar to those of titanium abutments for single implant crowns in the posterior area. Materials and Methods: A systematic search of two databases (Medline/PubMed and Cochrane Library) was performed by two independent reviewers for articles published between January 2004 and July 2014. The electronic search was complemented by a hand search of the following journals from the same period: Journal of Periodontology, Clinical Oral Implants Research, International Journal of Prosthodontics, and International Journal of Oral and Maxillofacial Implants. Studies included were published in English, evaluated single implant crowns, and performed a mean observation a 1 year. Any disagreement between the reviewers was solved by means of a discussion. Forest plot and funnel were used to compare zirconia and titanium abutments. Results: The search strategy identified 669 studies. Of these, 11 studies were included and only 6 studies were selected for meta-analysis. The pooled results for fixed implant single crowns in posterior areas showed a 5-year success rate of 99.3% for zirconia abutments and 99.57% for titanium abutments. There was no statistical difference regarding veneer failure (P = .26). The pooled results of these studies showed that the mean bone loss was 0.38 +/- 0.87 mm for zirconia and 0.2 +/- 0.13 mm for titanium abutments. Conclusion: The use of zirconia abutments for single implant-fixed crowns in posterior regions is questionable due to the absence of long-term data. The short-term results of zirconia abutments regarding mechanical and biologic responses are similar to titanium abutments. Caution when using zirconia abutments in posterior regions is necessary until further clinical evidence shows favorable long-term results.en
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
dc.description.affiliationUniv Toronto, Fac Dent, Dept Clin Sci, Toronto, ON, Canada
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
dc.format.extent233-244
dc.identifierhttp://dx.doi.org/10.11607/ijp.4349
dc.identifier.citationInternational Journal Of Prosthodontics. Hanover Park: Quintessence Publishing Co Inc, v. 29, n. 3, p. 233-244, 2016.
dc.identifier.doi10.11607/ijp.4349
dc.identifier.issn0893-2174
dc.identifier.lattes9719883814872582
dc.identifier.urihttp://hdl.handle.net/11449/161517
dc.identifier.wosWOS:000376213500007
dc.language.isoeng
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofInternational Journal Of Prosthodontics
dc.relation.ispartofsjr0,891
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleAre Zirconia Implant Abutments Safe and Predictable in Posterior Regions? A Systematic Review and Meta-Analysisen
dc.typeResenhapt
dcterms.rightsHolderQuintessence Publishing Co Inc
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes2336450644149867[2]
unesp.author.lattes9719883814872582
unesp.author.orcid0000-0003-3020-5253[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos