Logotipo do repositório
 

Publicação:
CFD study of the transient wet gas flow behavior through orifice plate flow meters

dc.contributor.authorWeise, Josiane
dc.contributor.authorBaliño, Jorge L.
dc.contributor.authorPaladino, Emilio E.
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2022-04-28T19:47:02Z
dc.date.available2022-04-28T19:47:02Z
dc.date.issued2021-12-01
dc.description.abstractDifferential pressure flow meters are widely used in wet gas flow measurement, typically, combined with a method to determine the liquid fraction. An alternative with significant advantages for industry, in term of cost, operation and maintenance, is determining the liquid fraction based on its relation with the statistical parameters of transient differential pressure signal fluctuations. In this way, a single measurement device can provide mass flow rate and liquid fraction simultaneously. For this method to be more feasible in the wet gas flow measurement, it is essential to understand how the differential pressure signal fluctuations and the gas–liquid flow behavior at the restriction are correlated. On this basis, this paper presents a transient 3D Computational Fluid Dynamics (CFD) study of the wet gas flow through an orifice plate, operating under field conditions, using the two-fluid model. Steady-state results, calculated from the time averaging of the transient solution, for the over-reading OR parameter were validated with experimental field data and results obtained by correlations available in the literature, showing very good agreement. The transient results from simulations presented a trend in agreement with experimental data from the literature, showing a positive correlation of the standard deviation of differential pressure signal with liquid fraction upstream of the orifice plate. However, these results should be analyzed qualitatively due to model limitations, mainly related to the interfacial transfer closure in gas–liquid flows with changing phase morphologies. Despite this fact, some important insights regarding the 3D transient flow structure with a practical value were obtained from the model.en
dc.description.affiliationSINMEC - Computational Fluid Dynamics Laboratory Mechanical Engineering Department Federal University of Santa Catarina
dc.description.affiliationDepartment of Mechanical Engineering Politechnic School State University of São Paulo, Av. Prof. Mello Moraes, 2231Cidade Universitária
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipPetrobras
dc.description.sponsorshipIdPetrobras: 2014/00624-7
dc.identifierhttp://dx.doi.org/10.1016/j.flowmeasinst.2021.102077
dc.identifier.citationFlow Measurement and Instrumentation, v. 82.
dc.identifier.doi10.1016/j.flowmeasinst.2021.102077
dc.identifier.issn0955-5986
dc.identifier.scopus2-s2.0-85118751961
dc.identifier.urihttp://hdl.handle.net/11449/222824
dc.language.isoeng
dc.relation.ispartofFlow Measurement and Instrumentation
dc.sourceScopus
dc.subjectDifferential pressure fluctuations
dc.subjectOrifice plate meter
dc.subjectOver-reading
dc.subjectTwo-fluid model
dc.subjectWet gas
dc.titleCFD study of the transient wet gas flow behavior through orifice plate flow metersen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.orcid0000-0002-2926-7353[1]
unesp.author.orcid0000-0001-5788-073X[3]

Arquivos

Coleções