Publicação: Effects of height and overactivation on a composite nickel-titanium T-loop
Carregando...
Arquivos
Data
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Tipo
Artigo
Direito de acesso
Acesso aberto

Resumo
Objective Evaluate the effect of height and overactivation on the force system produced by composite nickel-titanium T-loops. Material and Methods Forty nickel-titanium/stainless steel (SS) T-loops were divided into four groups according to height (7 or 6 mm) and activation/deactivation protocol (7 mm or 7 mm with 2 mm of overactivation). An Orthodontic Force Tester recorded the y-axis force and the x-axis moment produced for each 0.5 mm of deactivation, while the moment(x)-to-force(y) (M/F) ratio was calculated. The data were analyzed by three analyses of variance of repeated measures to detect differences and interactions between height and protocol on the three variables. Results T-loops with a height of 6 mm produced higher forces (2.97 N vs. 2.66 N) than those of 7 mm. The moments were similar, whereas the M/F was larger for the 7-mm loops (5.76 mm vs. 4.92 mm). The conventional activation produced higher forces (2.99 N vs. 2.64 N), higher moments (16.2 Nmm vs. 13.59 Nmm) but the same M/F. The M/F showed an interaction with deactivation. Conclusion The 6-mm-high T-loops produced higher forces, but lower M/F. The conventional protocol produced higher forces and moments. The M/F ratio was similar for both protocols, but overactivation produced a nearly constant M/F throughout deactivation. The use of a 7-mm-high overactivated segmented nickel-titanium loop might improve the performance of orthodontic space closure.
Descrição
Palavras-chave
Alloys, Loops, Nickel-titanium, Space Closure
Idioma
Inglês
Como citar
Journal of the World Federation of Orthodontists, v. 6, n. 3, p. 120-126, 2017.