dc.description.abstractTransdutores piezelétricos são amplamente utilizados em muitos métodos não destrutivos para a detecção de danos estruturais em aplicações de monitoramento de integridade estrutural ou SHM (Structural Health Monitoring). Dentre os vários métodos não destrutivos, a técnica da impedância eletromecânica (E/M) é conhecida por utilizar cerâmicas piezelétricas pequenas e finas que desempenham simultaneamente as funções de atuador e sensor. O método convencional de instalação dessas cerâmicas piezelétricas na estrutura é utilizando um adesivo de alta rigidez como cola a base de epóxi ou cianoacrilato. No entanto, alguns estudos propõem métodos alternativos de instalação do transdutor, visando a sua reutilização ou que permitam o monitoramento em condições adversas sob as quais a instalação direta do sensor não seria possível. Assim, esta dissertação de mestrado apresenta uma análise experimental comparativa entre os principais métodos de acoplamento entre o transdutor piezelétrico e a estrutura monitorada em sistemas de SHM baseados na técnica da impedância eletromecânica (E/M). Os acoplamentos dos transdutores piezelétricos foram realizados pelos métodos da instalação direta, também conhecida como instalação convencional, por acoplamento magnético e lâminas de alumínio. O transdutor utilizado para os métodos de acoplamento foi o diafragma piezelétrico, comumente conhecido como buzzer. Testes com os três métodos de instalação foram realizados em estruturas de alumínio e o dano estrutural foi induzido por meio de adição de massa metálica (porca de aço), fixada diretamente na estrutura com cola a base de cianoacrilato. A análise comparativa entre os métodos de instalação foi realizada utilizando índices de danos obtidos das assinaturas de impedância elétrica dos diafragmas piezelétricos, além da função de resposta em frequência (FRF) e da densidade espectral de potência obtida pelo método da quebra do grafite. Os resultados experimentais apontam características importantes para os métodos de instalação, os quais têm influência significativa sobre a resposta em frequência e sensibilidade para a detecção de danos estruturais.pt
dc.description.abstractPiezoelectric transducers are widely used in many non-destructive methods for detecting structural damage in Structural Health Monitoring (SHM) applications. Among the various techniques for detecting structural damage, the electromechanical impedance (EMI) technique is known to use fine and small piezoelectric ceramics that simultaneously perform the actuator and sensor functions. The conventional method of installing these piezoelectric ceramics in the structure is by using a high stiffness adhesive such as epoxy or cyanoacrylate based glue. However, some studies propose alternative methods of installing the transducer for reuse or to allow monitoring under adverse conditions under which direct sensor installation would not be possible. Thus, this master's thesis presents a comparative experimental analysis between the main coupling methods between the piezoelectric transducer and the monitored structure in SHM systems based on the electromechanical impedance technique. The piezoelectric transducer couplings were made by direct installation methods, also known as conventional installation, by magnetic coupling and aluminum foils. The transducer used for the coupling methods was the piezoelectric diaphragm, commonly known as buzzer. Tests with these methods were carried out on aluminum structures and the structural damage was induced using metallic masses (steel nuts), fixed directly to the structure with cyanoacrylate-based glue. The comparison of the results analysis between the coupling methods was performed using the indices of damages obtained from electrical impedance signatures of the piezoelectric diaphragm, the frequency response function (FRF) and the power spectral density (PSD) obtained by pencil lead break (PLB) test. The experimental results indicate important characteristics for each installation method and that the mounting method has a significant influence on the frequency response and sensitivity for the detection of structural damage.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 2015/02500-6
dc.identifier.aleph000887203
dc.identifier.capes33004056087P2
dc.identifier.lattes2426330204919814
dc.identifier.orcid0000-0002-1200-4354
dc.identifier.urihttp://hdl.handle.net/11449/150859
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso aberto
dc.subjectTransdutores piezelétricospt
dc.subjectSHMpt
dc.subjectImpedância eletromecânicapt
dc.subjectInstalaçãopt
dc.subjectDanopt
dc.subjectPiezoelectric transducersen
dc.subjectElectromechanical impedanceen
dc.subjectMountingen
dc.subjectDamageen
dc.titleDesempenho dos métodos de instalação de transdutores piezelétricos em sistemas de monitoramento de integridade estrutural baseados na impedância eletromecânicapt
dc.title.alternativePerformance of installation methods in piezoelectrics transducers in structural integrity monitoring systems based on electromechanical impedanceen
dc.typeDissertação de mestrado
dspace.entity.typePublication
unesp.advisor.lattes2426330204919814
unesp.advisor.orcid0000-0002-1200-4354
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Baurupt
unesp.embargoOnlinept
unesp.graduateProgramEngenharia Elétrica - FEBpt
unesp.knowledgeAreaAutomaçãopt
unesp.researchAreaMecatrônicapt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
silveira_rzm_me_bauru.pdf
Tamanho:
2.24 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
3.07 KB
Formato:
Item-specific license agreed upon to submission
Descrição: