Logo do repositório
 

Efeito da plataforma Switching sobre os tecidos peri-implantares: estudo experimental em cães

dc.contributor.advisorBotticelli, Daniele [UNESP]
dc.contributor.authorScala, Alessandro [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:32:40Z
dc.date.available2014-06-11T19:32:40Z
dc.date.issued2011-09-09
dc.description.abstractObjetivo: Avaliar a influência da plataforma Switching sobre a remodelação dos tecidos peri-implantares. Material e métodos: Em 6 cães labradores, foram extraídos os pré-molares e primeiro molares inferiores bilateralmente. Após 3 meses de cicatrização, na região correpondente ao 1º molar, foi instalado um implante cônico em cada lado da mandíbula, com o ombro do mesmo posicionado ao nível da crista óssea alveolar vestibular. No lado direito da mandíbula, foi utilizado um pilar de diâmetro reduzido em relação à plataforma do implante, criando uma incompatibilidade de 0,85 milímetros (grupo teste), enquanto no lado esquerdo selecionou-se um pilar do mesmo diâmetro da plataforma do implante (grupo controle). Os retalhos foram suturados permitindo a cicatrização não-submersa. Após 4 meses, os animais foram eutanasiados para obtenção dos cortes histológicos para avaliação histométrica. Resultados: Todos os implantes apresentaram-se completamente osseointegrados. No grupo teste foram observados que os níveis ósseos apresentaram-se superiores ao grupo controle. No entanto, a diferença estatisticamente significativa foi encontrada apenas na região vestibular e na região proximal. A dimensão vertical dos tecidos moles foi maior no grupo controle em comparação ao grupo teste. No entanto, foi encontrada diferença estatisticamente significativa apenas na vestibular. Conclusões: O presente estudo demonstrou diferenças nas dimensões dos tecidos duros e moles peri-implantares (vestibular e proximal) como resultado da incompatibilidade do implante / pilar de 0,85 milímetros, quando o ombro do implante foi posicionado ao nível da crista óssea vestibularpt
dc.description.abstractAim: to evaluate the effect of platform switching on the peri-implant tissue remodeling. Material & methods: Mandibular premolars and first molars of 6 Labrador dogs were extracted bilaterally. After 3 months of healing, 1 tapered implant was installed on each side of the mandibular molar region with the implant shoulder placed at the level of the alveolar buccal bony crest. On the right side of the mandible, an abutment of reduced diameter in relation to the platform of the implant was used creating a mismatch of 0.85mm (test), while an abutment of the same diameter of the implant platform was affixed in the left side of the mandible (control). The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment. Results: All implants were completely osseointegrated. Bone levels were superior at the test than at the control sites. However, statistically significant differences were found only at the buccal and proximal aspects. The soft tissue vertical dimension was higher at the control compared to the test sites. However, statistically significant differences were demonstrated only or at the buccal aspects. Conclusions: The present study demonstrated differences in peri-implant (buccal and proximal) hard and soft tissue dimensions as a result of an implant/abutment mismatch of 0.85mm, when the implant shoulder was placed at the level of the buccal bony cresten
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent64 f. : il. + 1 CD-ROM
dc.identifier.aleph000696186
dc.identifier.capes33004021011P0
dc.identifier.citationSCALA, Alessandro. Efeito da plataforma Switching sobre os tecidos peri-implantares: estudo experimental em cães. 2011. 64 f. Tese (doutorado) - Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araçatuba, 2011.
dc.identifier.filescala_a_dr_araca.pdf
dc.identifier.urihttp://hdl.handle.net/11449/103316
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.sourceAleph
dc.subjectOssos - Regeneraçãopt
dc.subjectImplantes dentáriospt
dc.subjectDental implantspt
dc.titleEfeito da plataforma Switching sobre os tecidos peri-implantares: estudo experimental em cãespt
dc.typeTese de doutoradopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.graduateProgramOdontologia - FOApt
unesp.knowledgeAreaImplantodontiapt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
scala_a_dr_araca.pdf
Tamanho:
861.13 KB
Formato:
Adobe Portable Document Format