Logotipo do repositório
 

Publicação:
The Ability of Different Nickel-Titanium Rotary Instruments To Induce Dentinal Damage During Canal Preparation

dc.contributor.authorSouza Bier, Carlos Alexandre [UNESP]
dc.contributor.authorShemesh, Hagay
dc.contributor.authorTanomaru-Filho, Mario [UNESP]
dc.contributor.authorWesselink, Paul R.
dc.contributor.authorWu, Min-Kai
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionPedodontol Acad Ctr Dent Amsterdam
dc.date.accessioned2014-05-20T13:47:10Z
dc.date.available2014-05-20T13:47:10Z
dc.date.issued2009-02-01
dc.description.abstractThe purpose of this study was to compare the incidence of dentinal defects (fractures and craze lines) after canal preparation with different nickel-titanium rotary files. Two hundred sixty mandibular premolars were selected. Forty teeth were left unprepared (n = 40). The other teeth were prepared either with manual Flexofiles (n = 20) or with different rotary files systems: ProTaper (Dentsply-Maillefer, Ballaigues, Switzerland), ProFile (Dentsply-Maillefer), SystemGT (Dentsply-Maillefer), or S-ApeX (FKG Dentaire, La Chaux-de-Fonds, Switzerland) (n = 50 each). Roots were then sectioned 3, 6, and 9 mm from the apex and observed under a microscope. The presence of dentinal defects was noted. There was a significant difference in the appearance of defects between the groups (p < 0.05). No defects were found in the unprepared roots and those prepared with hand files and S-ApeX. ProTaper, ProFile, and GT preparations resulted in dentinal defects in 16%, 8%, and 4% of teeth, respectively. Some endodontic preparation methods might damage the root and induce dentinal defects. (J Endod 2009;35:236-238)en
dc.description.affiliationSão Paulo State Univ, UNESP, Dept Restorat Dent, Araraquara Dent Sch, Araraquara, SP, Brazil
dc.description.affiliationPedodontol Acad Ctr Dent Amsterdam, Dept Cardiol, Amsterdam, Netherlands
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Dept Restorat Dent, Araraquara Dent Sch, Araraquara, SP, Brazil
dc.format.extent236-238
dc.identifierhttp://dx.doi.org/10.1016/j.joen.2008.10.021
dc.identifier.citationJournal of Endodontics. New York: Elsevier B.V., v. 35, n. 2, p. 236-238, 2009.
dc.identifier.doi10.1016/j.joen.2008.10.021
dc.identifier.issn0099-2399
dc.identifier.urihttp://hdl.handle.net/11449/16752
dc.identifier.wosWOS:000263074700019
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofJournal of Endodontics
dc.relation.ispartofjcr2.886
dc.relation.ispartofsjr1,585
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectCraze linesen
dc.subjectdentinal defectsen
dc.subjectnickel-titanium instrumentsen
dc.subjectroot canal preparationen
dc.titleThe Ability of Different Nickel-Titanium Rotary Instruments To Induce Dentinal Damage During Canal Preparationen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.orcid0000-0002-4840-048X[2]
unesp.author.orcid0000-0002-2574-4706[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: