Logotipo do repositório
 

Publicação:
Comparison of Macintosh and AirtraqTM laryngoscopes in obese patients placed in the ramped position

Carregando...
Imagem de Miniatura

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Wiley-Blackwell

Tipo

Artigo

Direito de acesso

Acesso restrito

Resumo

This study compared intubation conditions produced by the Macintosh and AirtraqTM laryngoscopes when used in obese patients in the ramped position. One hundred and thirty-two patients having bariatric surgery were placed in the ramped position and randomly assigned to have their tracheas intubated using either the Macintosh (n = 64) or an Airtraq (n = 68) laryngoscope. Mean (SD) intubation times were 37 (23) s and 14 (3) s for Macintosh and Airtraq, respectively (p < 0.0001). Compared with the Macintosh laryngoscope, the Airtraq laryngoscope provided an improved vocal cord view as assessed by the Cormack and Lehane score (number of patients with Cormack-Lehane scores of 1/2/3/4/37/20/4/3 for the Macintosh, and 65/3/0/0 for the Airtraq laryngoscopes, p < 0.0001). One patient in the Macintosh group had a failed intubation and intubation was achieved with the Airtraq. For obese patients in ramped position, Airtraq affords faster tracheal intubation than the Macintosh laryngoscope.

Descrição

Palavras-chave

Idioma

Inglês

Como citar

Anaesthesia. Hoboken: Wiley-blackwell, v. 67, n. 9, p. 980-985, 2012.