Publicação: Curing depth of composite resin light cured by LED and halogen light-curing units
dc.contributor.author | Calixto, L. R. [UNESP] | |
dc.contributor.author | Lima, D. M. [UNESP] | |
dc.contributor.author | Queiroz, R. S. [UNESP] | |
dc.contributor.author | Rastelli, Alessandra Nara de Souza [UNESP] | |
dc.contributor.author | Bagnato, V. S. | |
dc.contributor.author | Andrade, M. F. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2014-05-20T13:47:01Z | |
dc.date.available | 2014-05-20T13:47:01Z | |
dc.date.issued | 2008-11-01 | |
dc.description.abstract | The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters. | en |
dc.description.affiliation | UNESP, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil | |
dc.description.affiliation | USP, Phys Inst São Carlos, BR-13560970 São Carlos, SP, Brazil | |
dc.description.affiliationUnesp | UNESP, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil | |
dc.format.extent | 1365-1369 | |
dc.identifier | http://dx.doi.org/10.1134/S1054660X08110303 | |
dc.identifier.citation | Laser Physics. New York: Maik Nauka/interperiodica/springer, v. 18, n. 11, p. 1365-1369, 2008. | |
dc.identifier.doi | 10.1134/S1054660X08110303 | |
dc.identifier.issn | 1054-660X | |
dc.identifier.lattes | 6914969526213393 | |
dc.identifier.lattes | 2897622509429759 | |
dc.identifier.uri | http://hdl.handle.net/11449/16685 | |
dc.identifier.wos | WOS:000260854700030 | |
dc.language.iso | eng | |
dc.publisher | Maik Nauka/interperiodica/springer | |
dc.relation.ispartof | Laser Physics | |
dc.relation.ispartofjcr | 1.158 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Web of Science | |
dc.title | Curing depth of composite resin light cured by LED and halogen light-curing units | en |
dc.type | Artigo | pt |
dcterms.license | http://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0 | |
dcterms.rightsHolder | Maik Nauka/interperiodica/springer | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 901124bf-5736-4432-b057-7c29dec84b50 | |
relation.isDepartmentOfPublication.latestForDiscovery | 901124bf-5736-4432-b057-7c29dec84b50 | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
unesp.author.lattes | 6914969526213393[4] | |
unesp.author.lattes | 2897622509429759 | |
unesp.author.orcid | 0000-0001-9113-1206[2] | |
unesp.author.orcid | 0000-0002-6768-2670[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Odontologia Restauradora - FOAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: