Logotipo do repositório
 

Publicação:
Internal adaptation of cast titanium crowns

dc.contributor.authorDa Rocha, Sicknan Soares
dc.contributor.authorAdabo, Gelson Luis [UNESP]
dc.contributor.authorRibeiro, Ricardo Faria
dc.contributor.authorFonseca, Renata Garcia [UNESP]
dc.contributor.institutionUniversity Paulista (UNIP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-27T11:22:31Z
dc.date.available2014-05-27T11:22:31Z
dc.date.issued2007-07-01
dc.description.abstractAs the adaptation of titanium crowns obtained by Rematitan Plus investment, specific for titanium, is not recognized to be suitable, this study evaluated the effect of the concentration of the specific liquid and the temperature of the mold of investments on the internal misfit of crowns cast on commercially pure titanium. Individual dies of epoxy resin were obtained, representing teeth prepared for full-crown restoration with a 6-degree axial surface convergence angle and shoulder (1.0 mm). For the waxing of each crown, a ring-shaped stainless steel matrix (8.0mm internal diameter; 7.5 mm height) was adapted above the individual dies of epoxy resin. The Rematian Plus investment was mixed according to the manufacturer's instructions using two different concentrations of the specific liquid: 100%, 75%. Casting was performed in a Discovery Plasma Ar-arc vacuum-pressure casting machine with molds at temperatures of 430°C, 515°C and 600°C. The crowns were cleaned individually in a solution (1% HF + 13% HNO3) for 10 min using a ultrasonic cleaner, with no internal adaptations, and luted with zinc phosphate cement under a 5 kg static load. The crown and die assemblies were embedded in resin and sectioned longitudinally. The area occupied by cement was observed using stereoscopic lens (10X) and measured by the Leica Qwin image analysis system (mm2). The data for each experimental condition (n=8) were analyzed by Kruskal-Wallis non-parametric test (á=0.05). The results showed that liquid dilution and the increase in mold temperature did not significantly influence the levels of internal fit of the cast titanium crowns. The lowest means (±SD) of internal misfit were obtained for the 430°C/100%: (7.25 mm2 ±1.59) and 600°C/100% (8.8 mm2 ±2.25) groups, which presented statistically similar levels of internal misfit.en
dc.description.affiliationHealth Science Institute University Paulista (UNIP), Goiânia, GO
dc.description.affiliationDepartment of Dental Materials and Prosthodontics São Paulo State University Dental School of Araraquara, Araraquara, SP
dc.description.affiliationDepartment of Dental Materials and Prosthodontics University of São Paulo (USP) Dental School of Ribeirão Preto, Ribeirão Preto, SP
dc.description.affiliationDepartamento de Materiais Odontológicos e Prótese Faculdade de Odontologia de Araraquara Universidade Estadual Paulista/UNESP, Rua Humaitá, 1680, 14801-903. CP: 331. Araraquara, SP
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics São Paulo State University Dental School of Araraquara, Araraquara, SP
dc.description.affiliationUnespDepartamento de Materiais Odontológicos e Prótese Faculdade de Odontologia de Araraquara Universidade Estadual Paulista/UNESP, Rua Humaitá, 1680, 14801-903. CP: 331. Araraquara, SP
dc.format.extent247-252
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572007000400002
dc.identifier.citationJournal of Applied Oral Science, v. 15, n. 4, p. 247-252, 2007.
dc.identifier.doi10.1590/S1678-77572007000400002
dc.identifier.file2-s2.0-36448940135.pdf
dc.identifier.issn1678-7757
dc.identifier.issn1678-7765
dc.identifier.lattes2851339311179809
dc.identifier.lattes3041561340615890
dc.identifier.scieloS1678-77572007000400002
dc.identifier.scopus2-s2.0-36448940135
dc.identifier.urihttp://hdl.handle.net/11449/69760
dc.identifier.wosWOS:000256794400002
dc.language.isoeng
dc.relation.ispartofJournal of Applied Oral Science
dc.relation.ispartofjcr1.709
dc.relation.ispartofsjr0,645
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectDental alloys
dc.subjectDental casting investment
dc.subjectTitanium
dc.titleInternal adaptation of cast titanium crownsen
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/jaos/paboutj.htm
dspace.entity.typePublication
unesp.author.lattes2851339311179809
unesp.author.lattes3041561340615890
unesp.author.orcid0000-0002-0734-7926[2]
unesp.author.orcid0000-0001-6657-913X[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-36448940135.pdf
Tamanho:
171.22 KB
Formato:
Adobe Portable Document Format