Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2025 a 4 de janeiro de 2026.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

Logo do repositório

In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants

dc.contributor.authorSantana, Luís Carlos Leal [UNESP]
dc.contributor.authorIdogava, Henrique Takashi
dc.contributor.authorDe Foggi, Camila Cristina
dc.contributor.authorGuastaldi, Fernando Pozzi Semeghini
dc.contributor.authorNoritomi, Pedro Yoshito
dc.contributor.authorDos Reis, Barbara Araújo [UNESP]
dc.contributor.authorVaz, Luis Geraldo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionDental School
dc.contributor.institutionHarvard School of Dental Medicine
dc.contributor.institution3D Technology Core (NT3D)
dc.date.accessioned2025-04-29T18:41:40Z
dc.date.issued2023-09-01
dc.description.abstractShort dental implants with platform matching connection have been used for the rehabilitation of atrophic jaws whenever standard-length dental implants cannot be placed without prior bone augmentation. Yet, there remains a lack of data regarding the risk of technical failures when the all-on-4 configuration is performed in atrophic jaws with platform-switching distal short dental implants. Thus, the current study used the finite element method to evaluate the mechanical behavior at the level of the prosthetic components of the all-on-4 concept performed in atrophic mandible using short-length distal implants with platform switching (PSW) connection. Three models of the all-on-4 configuration were generated in human atrophic mandibles. The geometric models consisted of PSW connection tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) and straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants. A resultant force of 300 N was performed obliquely in the left side and posterior region of the prosthetic bar. The von Mises equivalent stress (σvm) and maximum and minimum principal stresses (σmax and σmin) were performed at level of the prosthetic components/implants and peri-implant bone crest, respectively. The general displacement of the models was also evaluated. The stress analysis was performed on the side of load application. The AO4S configuration showed the lowest values of σvm in the mesial left (ML) and distal left (DL) abutments (37.53 MPa and 232.77 MPa, respectively) and dental implants (91.53 MPa and 231.21 MPa, respectively). The AO4Sh configuration showed the highest values of σvm in the bar screw (102.36 MPa), abutment (117.56 MPa), and dental implant (293.73 MPa) of the ML area. Among the models, the highest values of σmax and σmin were noticed in the peri-implant bone crest of the AO4T design (131.48 MPa and 195.31 MPa, respectively). All models showed similar values of general displacements, which were concentrated in the mandible symphysis. The all-on-4 configurations designed with PSW connection and tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) or straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants were not associated with higher odds of technical failures. The AO4Sh design may be a promising option for the prosthetic rehabilitation of atrophic jaws.en
dc.description.affiliationDepartment of Diagnosis and Surgery São Paulo State University (Unesp) School of Dentistry, Araraquara
dc.description.affiliationDepartment of Mechanical Engineering Engineering School of São Carlos University of São Paulo (USP), São Carlos
dc.description.affiliationDepartment of Conservative Dentistry Federal University of Rio Grande do Sul (UFRGS) Dental School, Porto Alegre
dc.description.affiliationDepartment of Oral and Maxillofacial Surgery Massachusetts General Hospital (MGH) Harvard School of Dental Medicine
dc.description.affiliationRenato Archer Information Technology Center 3D Technology Core (NT3D), São Paulo
dc.description.affiliationDepartment of Dental Materials and Prosthodontics São Paulo State University (Unesp) School of Dentistry, Araraquara
dc.description.affiliationUnespDepartment of Diagnosis and Surgery São Paulo State University (Unesp) School of Dentistry, Araraquara
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics São Paulo State University (Unesp) School of Dentistry, Araraquara
dc.identifierhttp://dx.doi.org/10.1115/1.4062540
dc.identifier.citationJournal of Biomechanical Engineering, v. 145, n. 9, 2023.
dc.identifier.doi10.1115/1.4062540
dc.identifier.issn1528-8951
dc.identifier.issn0148-0731
dc.identifier.scopus2-s2.0-85163900296
dc.identifier.urihttps://hdl.handle.net/11449/299206
dc.language.isoeng
dc.relation.ispartofJournal of Biomechanical Engineering
dc.sourceScopus
dc.subjectbiomechanics
dc.subjectdental implant-abutment design
dc.subjectfinite element analysis
dc.subjectimplant-supported dental prosthesis
dc.subjectplatform switching
dc.titleIn Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implantsen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt

Arquivos