Repository logo

Evaluation of different composite resin finishing and polishing protocols by confocal laser scan microscopy

Abstract

Aim: This study aimed to analyze the influence of finishing and polishing (F/P) protocols on resin surface through roughness (Ra) values and laser scan microscopy observations. Methods: Forty-eight (n=48) resin specimens were sorted into four groups (n=12), according to the type of resin used: Filtek Z250 (Z250), Filtek Z350 (Z350), Filtek One Bulk Fill (BF), Filtek P60 (P60). The specimens were sorted into six groups according to the type of F/P system used (n=2/group): Control group, Diamond bur (KG Sorensen), Soflex Pop-On Discs (3M ESPE), Soflex Spiral (3M ESPE), Dura Gloss (American Burs), and Praxis (TDV). Results: The highest roughness values (Ra) were attributed to BF group for all F/P systems, except for the Soft-Lex PopOn discs. The Soft-Lex PopOn, Spiral, and Praxis discs presented a better performance for the surface treatment of the tested composite resins. Regardless of the restorative material, the use of diamond bur or single-step abrasive rubber (Dura Gloss) were associated with the highest Ra values. Conclusion: The effect of F/P systems on Ra is material-dependent and instrument or system-dependent.

Description

Keywords

Composite resins. Dental materials. Dental polishing

Language

English

Citation

Brazilian Journal of Oral Sciences, v. 21.

Related itens

Sponsors

Collections

Units

Departments

Undergraduate courses

Graduate programs

Other forms of access