Publicação: Assessing the surface roughness of a posterior resin composite: effect of surface sealing
dc.contributor.author | Takeuchi, CYG | |
dc.contributor.author | Flores, VHO | |
dc.contributor.author | Dibb, RGP | |
dc.contributor.author | Panzeri, H. | |
dc.contributor.author | Lara, EHG | |
dc.contributor.author | Dinelli, W. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2014-05-20T13:46:53Z | |
dc.date.available | 2014-05-20T13:46:53Z | |
dc.date.issued | 2003-05-01 | |
dc.description.abstract | This study assessed the in vitro influence of surface sealing on the surface roughness of a posterior resin composite before and after tooth-brushing. Thirty. specimens (13 nun diameter x 1 mm high) were fabricated from Filtek-P60 resin composite and randomly assigned to three groups (n=10): a non-sealed control and two groups sealed with one of the tested materials-a surface-penetrating sealant (Protect-it!-PI) and a one bottle adhesive system (Single Bond-SB). The samples were subjected to a surface roughness reading to determine the initial roughness, then submitted to simulated toothbrushing with 35,600 cycles for 100 minutes. Specimens were then cleaned and a post-abrasion surface roughness reading accomplished. Means (pm), recorded before (B) and after (A) toothbrushing, and standard deviations were: Control-(B): 0.032 (+/-0.005), (A): 0.054 (+/-0.005); PI-(B): 0.034 (+/-0.005), (A): 0.060 (+/-0.034); SB (B): 0.031 (+/-0.004), (A): 0.047 (+/-0.007). Data were tabulated and submitted to two-way ANOVA. No statistically significant difference was observed when the control and experimental groups were compared. However, a significant difference (p<0.05) was found between the measurements performed before and after toothbrushing. Based on these results, it may be concluded that using either a surface penetrating sealant or a one bottle adhesive system did not provide the optimization of superficial integrity. The use of a dentifrice and toothbrush resulted in significant alterations to the surface smoothness of the resin composite. | en |
dc.description.affiliation | São Paulo State Univ, UNESP, Araraquara Dent Sch, Dept Restorat Dent, São Paulo, Brazil | |
dc.description.affiliation | Univ São Paulo, Ribeirao Preto Dent Sch, Dept Operat Dent, São Paulo, Brazil | |
dc.description.affiliation | Univ São Paulo, Ribeirao Preto Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil | |
dc.description.affiliation | Univ São Paulo, Sch Pharmaceut Sci, Dept Pharmaceut Sci, São Paulo, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Araraquara Dent Sch, Dept Restorat Dent, São Paulo, Brazil | |
dc.format.extent | 281-286 | |
dc.identifier.citation | Operative Dentistry. Indianapolis: Operative Dentistry Inc., v. 28, n. 3, p. 281-286, 2003. | |
dc.identifier.issn | 0361-7734 | |
dc.identifier.uri | http://hdl.handle.net/11449/16629 | |
dc.identifier.wos | WOS:000182553800009 | |
dc.language.iso | eng | |
dc.publisher | Operative Dentistry Inc | |
dc.relation.ispartof | Operative Dentistry | |
dc.relation.ispartofjcr | 2.130 | |
dc.relation.ispartofsjr | 1,180 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Web of Science | |
dc.title | Assessing the surface roughness of a posterior resin composite: effect of surface sealing | en |
dc.type | Artigo | pt |
dcterms.rightsHolder | Operative Dentistry Inc | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 901124bf-5736-4432-b057-7c29dec84b50 | |
relation.isDepartmentOfPublication.latestForDiscovery | 901124bf-5736-4432-b057-7c29dec84b50 | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
unesp.author.orcid | 0000-0002-3247-0248[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Odontologia Restauradora - FOAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: