Publicação: Evaluation of a two-step pouring technique for implant-supported prostheses impression
dc.contributor.author | Assunção, Wirley Goncalves [UNESP] | |
dc.contributor.author | Delben, Juliana A. | |
dc.contributor.author | Santos, Paulo Henrique dos [UNESP] | |
dc.contributor.author | Tabata, Lucas F. | |
dc.contributor.author | Gomes, Erica A. | |
dc.contributor.author | Barão, Valentim A. R. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:24:47Z | |
dc.date.available | 2014-05-27T11:24:47Z | |
dc.date.issued | 2010-09-07 | |
dc.description.abstract | The aim of this study was to evaluate the efficacy of a pouring technique for implant-supported prostheses impressions. A metallic matrix (control group) with two implants positioned at 90 and 65 degrees was fabricated. The matrix was submitted to the direct transfer impression technique. In group CP (conventional pouring - n = 10), casts were obtained by the conventional pouring technique. In group EP (experimental pouring - n = 10), the analogs were embraced with latex tubes before the first pouring and then submitted to a second pouring. Vertical misfit and implants/analogs inclinations were evaluated. Data were analyzed by analysis of variance and Tukey's test (p < .05). Results demonstrated significant difference (p < .05) between control and experimental groups for misfit measurement in perpendicular implant/analog and between control group and group EP in leaning implant/analog. Considering inclination, there were significant differences (p < .05) between control and experimental groups for leaning analogs. Independently of the pouring technique, perpendicular implants produced more accurate casts. | en |
dc.format.extent | 8-12 | |
dc.identifier | http://www.actaodontologicalat.com/archivo/v23n1/fulltext/articulo2.pdf | |
dc.identifier.citation | Acta odontológica latinoamericana : AOL, v. 23, n. 1, p. 8-12, 2010. | |
dc.identifier.issn | 0326-4815 | |
dc.identifier.lattes | 4438747643373395 | |
dc.identifier.lattes | 0493479801083622 | |
dc.identifier.orcid | 0000-0002-4100-5153 | |
dc.identifier.scopus | 2-s2.0-77956205170 | |
dc.identifier.uri | http://hdl.handle.net/11449/71871 | |
dc.language.iso | eng | |
dc.relation.ispartof | Acta Odontológica Latinoamericana (AOL) | |
dc.relation.ispartofsjr | 0,264 | |
dc.rights.accessRights | Acesso aberto | pt |
dc.source | Scopus | |
dc.subject | Dental impression | |
dc.subject | Evaluation | |
dc.subject | Tooth prosthesis | |
dc.subject | Dental Impression Technique | |
dc.subject | Dental Prosthesis | |
dc.title | Evaluation of a two-step pouring technique for implant-supported prostheses impression | en |
dc.type | Artigo | pt |
dcterms.license | http://www.actaodontologicalat.com/peditorial.html | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 4438747643373395 | |
unesp.author.lattes | 0493479801083622[3] | |
unesp.author.orcid | 0000-0002-4100-5153[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |