Logotipo do repositório
 

Publicação:
Evaluation of a two-step pouring technique for implant-supported prostheses impression

dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorDelben, Juliana A.
dc.contributor.authorSantos, Paulo Henrique dos [UNESP]
dc.contributor.authorTabata, Lucas F.
dc.contributor.authorGomes, Erica A.
dc.contributor.authorBarão, Valentim A. R.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:24:47Z
dc.date.available2014-05-27T11:24:47Z
dc.date.issued2010-09-07
dc.description.abstractThe aim of this study was to evaluate the efficacy of a pouring technique for implant-supported prostheses impressions. A metallic matrix (control group) with two implants positioned at 90 and 65 degrees was fabricated. The matrix was submitted to the direct transfer impression technique. In group CP (conventional pouring - n = 10), casts were obtained by the conventional pouring technique. In group EP (experimental pouring - n = 10), the analogs were embraced with latex tubes before the first pouring and then submitted to a second pouring. Vertical misfit and implants/analogs inclinations were evaluated. Data were analyzed by analysis of variance and Tukey's test (p < .05). Results demonstrated significant difference (p < .05) between control and experimental groups for misfit measurement in perpendicular implant/analog and between control group and group EP in leaning implant/analog. Considering inclination, there were significant differences (p < .05) between control and experimental groups for leaning analogs. Independently of the pouring technique, perpendicular implants produced more accurate casts.en
dc.format.extent8-12
dc.identifierhttp://www.actaodontologicalat.com/archivo/v23n1/fulltext/articulo2.pdf
dc.identifier.citationActa odontológica latinoamericana : AOL, v. 23, n. 1, p. 8-12, 2010.
dc.identifier.issn0326-4815
dc.identifier.lattes4438747643373395
dc.identifier.lattes0493479801083622
dc.identifier.orcid0000-0002-4100-5153
dc.identifier.scopus2-s2.0-77956205170
dc.identifier.urihttp://hdl.handle.net/11449/71871
dc.language.isoeng
dc.relation.ispartofActa Odontológica Latinoamericana (AOL)
dc.relation.ispartofsjr0,264
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectDental impression
dc.subjectEvaluation
dc.subjectTooth prosthesis
dc.subjectDental Impression Technique
dc.subjectDental Prosthesis
dc.titleEvaluation of a two-step pouring technique for implant-supported prostheses impressionen
dc.typeArtigopt
dcterms.licensehttp://www.actaodontologicalat.com/peditorial.html
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes4438747643373395
unesp.author.lattes0493479801083622[3]
unesp.author.orcid0000-0002-4100-5153[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos