Publicação: Effect of clinical use of nickel-titanium springs
dc.contributor.author | Magno, Amanda Fahning | |
dc.contributor.author | Monini, André da Costa | |
dc.contributor.author | Capela, Marisa Veiga [UNESP] | |
dc.contributor.author | Martins, Lidia Parsekian [UNESP] | |
dc.contributor.author | Martins, Renato Parsekian [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2015-10-21T20:20:59Z | |
dc.date.available | 2015-10-21T20:20:59Z | |
dc.date.issued | 2015-07-01 | |
dc.description.abstract | Introduction: Our objectives were to determine whether there are changes on the load deflection rate (L/DP) and the average force (FP) of the superelastic pseudoplateau, and whether permanent deformation is changed in nickel-titanium closed-coil springs (CCSs) after 6 months of clinical use. Methods: Twenty-two nickel-titanium CCSs (Sentalloy 100 g; Dentsply GAC, York, Pa) were subjected to tensile mechanical testing at 37 degrees C on activations varying from 3.2 to 16.0 mm before and after 6 months of clinical use. A regression line was fitted over the most horizontal area of the unloading part of the stress-strain graph of every CCS, and its slope was used as L/DP. The FP was determined by the midpoint of the longest segment of the curve that could be fit within the regression line with a R-2 of at least 0.999, and permanent deformation was determined graphically by obtaining the strain value when the measured stress reached zero. The data were analyzed by 3 analyses of variance at 2 levels, with 5% of significance. Results: Time and activation significantly influenced the variables tested (P < 0.001). Time increased the L/DP and permanent deformation but decreased the FP. Activation decreased L/DP, FP, and permanent deformation. Significant interactions between time and activation were detected for FP (P = 0.013) and deformation (P < 0.001). Conclusions: After 6 months of active clinical use, the analyzed springs had a significant but small increase in their L/DP; FP dropped up to 88%, and the CCSs deformed up to 1.26 mm. | en |
dc.description.affiliationUnesp | Universidade Estadual Paulista, Departamento de Físico Química, Instituto de Química de Araraquara | |
dc.description.affiliationUnesp | Universidade Estadual Paulista, Departamento de Clínica Infantil, Faculdade de Odontologia de Araraquara | |
dc.format.extent | 76-82 | |
dc.identifier | http://www.sciencedirect.com/science/article/pii/S0889540615004254 | |
dc.identifier.citation | American Journal Of Orthodontics And Dentofacial Orthopedics. New York: Mosby-elsevier, v. 148, n. 1, p. 76-82, 2015. | |
dc.identifier.doi | 10.1016/j.ajodo.2015.02.028 | |
dc.identifier.issn | 0889-5406 | |
dc.identifier.lattes | 2105396012022450 | |
dc.identifier.lattes | 5782696565602340 | |
dc.identifier.uri | http://hdl.handle.net/11449/129091 | |
dc.identifier.wos | WOS:000357100100017 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | American Journal Of Orthodontics And Dentofacial Orthopedics | |
dc.relation.ispartofjcr | 1.842 | |
dc.relation.ispartofsjr | 1,289 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | Effect of clinical use of nickel-titanium springs | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
unesp.author.lattes | 2105396012022450 | |
unesp.author.lattes | 5782696565602340 | |
unesp.author.orcid | 0000-0002-9678-0798[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Clínica Infantil - FOAR | pt |
unesp.department | Físico-Química - IQAR | pt |