Logotipo do repositório
 

Publicação:
Evaluation of the thermoplasticity of gutta-percha and Resilon (R) using the Obtura II System at different temperature settings

dc.contributor.authorTanomaru-Filho, M. [UNESP]
dc.contributor.authorPinto, R. V. S. [UNESP]
dc.contributor.authorBosso, R. [UNESP]
dc.contributor.authorNascimento, C. A. [UNESP]
dc.contributor.authorBerbert, Fabio Luiz Camargo Villela [UNESP]
dc.contributor.authorGuerreiro-Tanomaru, J. M. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:47:10Z
dc.date.available2014-05-20T13:47:10Z
dc.date.issued2011-08-01
dc.description.abstractAim To analyse the thermoplasticity of several endodontic filling materials using the Obtura II System at different temperature settings.Methodology The following materials based on gutta-percha: Regular Obtura (OBT), Obtura Flow 150 (OBT F), Endo Flow (EDF), Odous (ODO) and the synthetic thermoplastic polymer material Resilon (RE) were heated using the Obtura II System at three temperature settings (140, 170 and 200 degrees C). Samples of the heated materials were placed on the sensor of a digital thermometer (THR-140; Instrutherm, São Paulo, Brazil) to determine their real temperature (RT) when the system was set at 140 degrees C (from 64.5 to 69 degrees C), 170 degrees C (from 73.8 to 77.5 degrees C) and 200 degrees C (from 83.6 degrees C for EDF and 100 degrees C for RE). Specimens (n = 30) were made by placing samples of each material in metallic ring moulds and compressing them between two glass slabs. After 24 h, specimens (n = 10) were heated at the different settings (RT) and submitted to compression under a 5-kg load. Plasticization was assessed by calculating the differences between the post-compression and initial diameters of each specimen. Data were submitted to ANOVA and Tukey's test at 5% significance.Results At 140 degrees C, Obtura Flow presented the highest thermoplasticity values and Regular Obtura, the lowest. At 170 degrees C, Obtura Flow and Resilon demonstrated greater plasticization. Resilon had the highest mean thermoplasticity values at 200 degrees C.Conclusions Thermoplasticity values were influenced both by the temperature settings on the Obtura II System and by the type of material analysed. Obtura Flow and Resilon had the highest mean thermoplasticity values.en
dc.description.affiliationUNESP, Araraquara Dent Sch, Dept Restorat Dent, Araraquara, Brazil
dc.description.affiliationUnespUNESP, Araraquara Dent Sch, Dept Restorat Dent, Araraquara, Brazil
dc.format.extent764-768
dc.identifierhttp://dx.doi.org/10.1111/j.1365-2591.2011.01889.x
dc.identifier.citationInternational Endodontic Journal. Malden: Wiley-blackwell, v. 44, n. 8, p. 764-768, 2011.
dc.identifier.doi10.1111/j.1365-2591.2011.01889.x
dc.identifier.issn0143-2885
dc.identifier.lattes0883153608402181
dc.identifier.orcid0000-0003-3292-3136
dc.identifier.urihttp://hdl.handle.net/11449/16751
dc.identifier.wosWOS:000292336400007
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofInternational Endodontic Journal
dc.relation.ispartofjcr3.015
dc.relation.ispartofsjr1,791
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectgutta-perchaen
dc.subjectroot canal filling materialsen
dc.subjectroot canal obturationen
dc.titleEvaluation of the thermoplasticity of gutta-percha and Resilon (R) using the Obtura II System at different temperature settingsen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes0883153608402181(5)
unesp.author.orcid0000-0001-5230-0492[5]
unesp.author.orcid0000-0002-2574-4706[1]
unesp.author.orcid0000-0002-0561-2685[3]
unesp.author.orcid0000-0003-0446-2037[6]
unesp.author.orcid0000-0003-3292-3136(5)
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: