dc.description.abstractTo evaluate the ability of low time microwaveexposureto inactivate and damage cell membrane integrity of C. albicans. Materials and Methods: Two 200ml C. albicans suspensions were obtained. Sterile dentures were placed in a beaker containing Experimental (ES) or Control suspensions (CS). ES was microwaved at 650 W for 1, 2, 3, 4 or 5 min. Suspensions were optically counted using Methylene blue dye as indicative of membrane-damaged cells; spread on Agar Sabouraud dextrose (ASD) for viability assay; or spectrophotometrically measured at 550nm. Cell-free solutions were submitted to content analyses of protein (Bradford and Pyrogallol red methods); Ca++ (Cresolphthalein Complexone method); DNA (spectrophotometer measurements at 260nm) and K+ (selective electrode technique). Data were analyzed by Student-t test and linear regression (α=0.05). In addition, flowcytometry analysis of Candida cells in suspensionwas performed using propidium iodide. Results: All ES cells demonstrated cell membrane damage at 3, 4 and 5 min,viable cells were nonexistent at 3, 4 and 5 min ES ASD plates and optical density of ES and CS was not significantly differentfor all exposition times. ES cells released highcontents of protein, K+ , Ca++ and DNA after 2 min exposition when compared to that of the CSs. Similar results were observed with flow cytometry analysiswith regard to the periodsof microwave exposure. Conclusions: Microwave irradiation inactivated C. albicansafter 3min and damaged cell membrane integrity after 2 min exposition.en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680, Centro, CEP 14801903, SP, Brasil
dc.description.affiliationDepartment of Dentistry, State University of Ponta Grossa - UEPG, Paraná, Brazil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680, Centro, CEP 14801903, SP, Brasil
dc.format.extent38-45
dc.identifierhttp://pubs.sciepub.com/ajidm/1/3/1/index.html
dc.identifier.citationAmerican Journal of Infectious Diseases and Microbiology, v. 1, n. 3, p. 38-45, 2013.
dc.identifier.doi10.12691/ajidm-1-3-1
dc.identifier.fileISSN2328-4056-2013-01-03-38-45.pdf
dc.identifier.issn2328-4056
dc.identifier.lattes5737127334248549
dc.identifier.lattes8867670539105403
dc.identifier.lattes8605087609369467
dc.identifier.urihttp://hdl.handle.net/11449/126130
dc.language.isopor
dc.relation.ispartofAmerican Journal of Infectious Diseases and Microbiology
dc.rights.accessRightsAcesso abertopt
dc.sourceCurrículo Lattes
dc.subjectMicrowavesen
dc.subjectCandida albicansen
dc.subjectDenture stomatitisen
dc.subjectDisinfectionen
dc.subjectDentureen
dc.titleCell membrane integrity of candida albicans after different protocols of microwave irradiationen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes5737127334248549
unesp.author.lattes8605087609369467
unesp.author.lattes8867670539105403[7]
unesp.author.orcid0000-0002-9135-3455[2]
unesp.author.orcid0000-0002-9231-1994[7]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
ISSN2328-4056-2013-01-03-38-45.pdf
Tamanho:
195.5 KB
Formato:
Adobe Portable Document Format