Influence of Opening Type in Axially Compressed Castellated Columns

dc.contributor.authorGomes, Arthur F. F.
dc.contributor.authorMesquita, Leonardo C.
dc.contributor.authorRodrigues, Edson F. C.
dc.contributor.authorArroyo, Felipe N.
dc.contributor.authorAquino, Vinícius B. M. [UNESP]
dc.contributor.authorSantos, Herisson F.
dc.contributor.authorPanzera, Túlio H.
dc.contributor.authorLahr, Francisco A. R.
dc.contributor.authorChahud, Eduardo
dc.contributor.authorBranco, Luis A. M. N.
dc.contributor.authorChristoforo, André L.
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)
dc.contributor.institutionPontifical Catholic University of Rio de Janeiro
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidade Estadual de Maringá (UEM)
dc.contributor.institutionFederal University of São João del-Rei
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Federal de Minas Gerais (UFMG)
dc.date.accessioned2025-04-29T20:15:11Z
dc.date.issued2023-07-01
dc.description.abstractRecently, castellated columns have been increasingly used in buildings because of their flexibility, easy compatibility and potential savings due to less steel consumption. However, there is a lack of research related to the subject. In view of that, this work evaluates the influence of the opening type and size on the resistant capacity of the column, considering a nonlinear plastic analysis by the finite element method (792 simulations). For this, columns without openings were modeled to validate the methodology proposed. After validation, a nonlinear buckling analysis of castellated columns was performed. In this study, different cut patterns of the beam web are evaluated, as well as residual stresses, material and geometric imperfections, based on a statistical design. The loads obtained by castellated columns and columns without web are compared. Also, the resistance reduction factors associated with global buckling (χ) for castellated profiles are compared to the values proposed by ABNR NBR 8800 (2008). Furthermore, statistically, there are no differences between the opening types evaluated. Finally, in order to contribute to the design of castellated columns, equations based on regression models were found to predict the load capacity of these elements.en
dc.description.affiliationDepartment of Civil Engineering Federal University of São Carlos, São Paulo
dc.description.affiliationDepartment of Civil Engineering Pontifical Catholic University of Rio de Janeiro, Rio de Janeiro
dc.description.affiliationDepartment of Civil Engineering São Paulo State University, São Paulo
dc.description.affiliationDepartment of Engineering Federal Institute of Rondônia, Rondônia
dc.description.affiliationDepartment of Mechanical Engineering Federal University of São João del-Rei, Minas Gerais
dc.description.affiliationDepartment of Structural Engineering University of São Paulo, São Paulo
dc.description.affiliationDepartment of Materials and Construction Engineering Federal University of Minas Gerais, Minas Gerais
dc.description.affiliationUnespDepartment of Civil Engineering São Paulo State University, São Paulo
dc.description.sponsorshipDepartment of Industry, Innovation, Science, Research and Tertiary Education, Australian Government
dc.identifierhttp://dx.doi.org/10.3390/buildings13071851
dc.identifier.citationBuildings, v. 13, n. 7, 2023.
dc.identifier.doi10.3390/buildings13071851
dc.identifier.issn2075-5309
dc.identifier.scopus2-s2.0-85166253113
dc.identifier.urihttps://hdl.handle.net/11449/309332
dc.language.isoeng
dc.relation.ispartofBuildings
dc.sourceScopus
dc.subjectAbaqus
dc.subjectcastellated profiles
dc.subjectfinite element analysis
dc.subjectnonlinear analysis
dc.subjectsteel
dc.titleInfluence of Opening Type in Axially Compressed Castellated Columnsen
dc.typeArtigopt
dspace.entity.typePublication
unesp.author.orcid0000-0001-5764-5334[2]
unesp.author.orcid0000-0002-9028-0565[3]
unesp.author.orcid0000-0001-8226-172X[4]
unesp.author.orcid0000-0001-7091-456X[7]
unesp.author.orcid0000-0002-3510-8498[8]
unesp.author.orcid0000-0002-2538-3525[10]
unesp.author.orcid0000-0002-4066-080X[11]

Arquivos

Coleções