Logotipo do repositório
 

Publicação:
Attachment shape and its influence on aligner orthodontics: Part I

dc.contributor.authorMartins, Renato Parsekian [UNESP]
dc.contributor.authorParizotto, Julianna [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionBaylor College of Dentistry
dc.contributor.institutionClínica de Ortodontia Dental Press
dc.contributor.institutionABO Goiás
dc.date.accessioned2022-04-29T08:28:35Z
dc.date.available2022-04-29T08:28:35Z
dc.date.issued2019-01-01
dc.description.abstractSuccessful treatment with aligners involves much more than the virtual planning; mechanical knowledge is also needed. Common mechanical knowledge acquired with conventional orthodontics with fixed appliance is not enough to fully understand aligner mechanics, specially with attachments. Their use is mandatory in challenging movements, such as extrusion. The design of the attachment that will be used plays an important role in aligner adaptation and, combined with the adequate amount of activation, allows predictable treatment with aligners.en
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Odontologia de Araraquara
dc.description.affiliationTexas A&M University Baylor College of Dentistry
dc.description.affiliationCiências Odontológicas (área de Ortodontia) Universidade Estadual Paulista Faculdade de Odontologia de Araraquara
dc.description.affiliationDental Press Journal of Orthodontics e da Revista Clínica de Ortodontia Dental Press
dc.description.affiliationCurso de Especialização em Ortodontia ABO Goiás
dc.description.affiliationUniversidade de São Paulo Hospital de Reabilitação de Anomalias Craniofaciais
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Odontologia de Araraquara
dc.description.affiliationUnespCiências Odontológicas (área de Ortodontia) Universidade Estadual Paulista Faculdade de Odontologia de Araraquara
dc.format.extent29-34
dc.identifierhttp://dx.doi.org/10.14436/1676-6849.18.6.028-034.bio
dc.identifier.citationRevista Clinica de Ortodontia Dental Press, v. 18, n. 6, p. 29-34, 2019.
dc.identifier.doi10.14436/1676-6849.18.6.028-034.bio
dc.identifier.issn1676-6849
dc.identifier.scopus2-s2.0-85081303835
dc.identifier.urihttp://hdl.handle.net/11449/228778
dc.language.isopor
dc.relation.ispartofRevista Clinica de Ortodontia Dental Press
dc.sourceScopus
dc.subjectClear aligner appliances
dc.subjectOrthodontic movement
dc.subjectOrthodontics
dc.titleAttachment shape and its influence on aligner orthodontics: Part Ien
dc.titleFormato dos attachments e sua influência na movimentação com alinhadores: Parte Ipt
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentClínica Infantil - FOARpt

Arquivos