Logotipo do repositório
 

Publicação:
Reliable assessment of forearm photoageing by high-frequency ultrasound: a cross-sectional study

dc.contributor.authorCaetano, L. de V. N.
dc.contributor.authorSoares, J. L. M.
dc.contributor.authorBagatin, E.
dc.contributor.authorMiot, H. A. [UNESP]
dc.contributor.institutionUniversidade Federal de São Paulo (UNIFESP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-12-07T15:37:42Z
dc.date.available2015-12-07T15:37:42Z
dc.date.issued2015-09-09
dc.description.abstractHigh-frequency ultrasound is a non-invasive tool used in skin ageing research to assess dermis thickness and echogenicity. This study evaluated the reliability of a range of high-frequency ultrasound parameters and tested their correlation with age and a validated clinical scale for the assessment of forearm skin photoageing; the difference between two body sites according to environmental exposition patterns was also investigated. Twenty-three volunteers aged 28-82 years were divided into three groups according to forearm photoageing degree. A 20 MHz ultrasound unit was used to obtain cross-sectional images of the skin by two trained investigators on two different sites: the dorsal forearm (chronically photoexposed skin) and the proximal medial arm (non-photoexposed skin). Several echogenicity parameters were studied for each skin compartment: total dermis, upper dermis and lower dermis, and the ratio between upper and lower dermis. The intraclass correlation coefficient (for complete agreement) between investigators was higher for upper and total dermis echogenicity measures compared with the lower dermis. At the non-photoexposed site, the upper and lower dermis parameter ratio was better correlated with age. At the photoexposed area, total dermis parameters demonstrated higher correlations with clinical score. The authors discuss the choice of parameters for forearm photoageing assessment using high-frequency ultrasound.en
dc.description.affiliationDermatology Department, Universidade Federal de São Paulo - UNIFESP, R Borges Lagoa, 508, São Paulo, SP, 04038-001, Brazil.
dc.description.affiliationDepartment of Dermatology and Radiotherapy, Universidade Estadual Paulista Julio de Mesquita Filho - UNESP, Campus Universitário de Rubião Jr., Botucatu, SP, 18618-000, Brazil.
dc.description.affiliationUnespDepartment of Dermatology and Radiotherapy, Universidade Estadual Paulista Julio de Mesquita Filho - UNESP, Campus Universitário de Rubião Jr., Botucatu, SP, 18618-000, Brazil.
dc.identifierhttp://dx.doi.org/10.1111/ics.12272
dc.identifier.citationInternational Journal Of Cosmetic Science, 2015.
dc.identifier.doi10.1111/ics.12272
dc.identifier.issn1468-2494
dc.identifier.lattes2543633050941005
dc.identifier.pubmed26352387
dc.identifier.urihttp://hdl.handle.net/11449/131565
dc.language.isoeng
dc.publisherSociety of Cosmetic Scientists and the Société Française de Cosmétologie.
dc.relation.ispartofInternational Journal Of Cosmetic Science
dc.relation.ispartofsjr0,548
dc.rights.accessRightsAcesso restrito
dc.sourcePubMed
dc.subjectSafety testingen
dc.subjectSkin ageingen
dc.subjectSkin physiology/structureen
dc.subjectStatisticsen
dc.subjectUltrasonographyen
dc.titleReliable assessment of forearm photoageing by high-frequency ultrasound: a cross-sectional studyen
dc.typeArtigo
dcterms.rightsHolderSociety Of Cosmetic Scientists And The Société Française DeCosmétologie.
dspace.entity.typePublication
unesp.author.lattes2543633050941005
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentDermatologia e Radioterapia - FMBpt

Arquivos