Logotipo do repositório
 

Publicação:
Comparison of Transpulmonary Thermodilution and Calibrated Pulse Contour Analysis with Pulmonary Artery Thermodilution Cardiac Output Measurements in Anesthetized Dogs

dc.contributor.authorGarofalo, N. A.
dc.contributor.authorTeixeira-Neto, F. J.
dc.contributor.authorRodrigues, J. C.
dc.contributor.authorCerejo, S. A.
dc.contributor.authorAguiar, A J A
dc.contributor.authorBecerra-Velásquez, D. R.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T16:48:58Z
dc.date.available2018-12-11T16:48:58Z
dc.date.issued2016-07-01
dc.description.abstractBACKGROUND: Transpulmonary thermodilution (TPTDCO ) and calibrated pulse contour analysis (PCACO ) are alternatives to pulmonary artery thermodilution cardiac output (PATDCO ) measurement. HYPOTHESIS: Ten mL of ice-cold thermal indicator (TI10 ) would improve the agreement and trending ability between TPTDCO and PATDCO compared to 5 mL of indicator (TI5 ) (Phase-1). The agreement and TA between PCACO and PATDCO would be poor during changes in systemic vascular resistance (SVR) (Phase-2). ANIMALS: Eight clinically normal dogs (20.8-31.5 kg). METHODS: Prospective, experimental study. Simultaneous TPTDCO and PATDCO (averaged from 3 repetitions) using TI5 and TI10 were obtained during isoflurane anesthesia combined or not with remifentanil or dobutamine (Phase-1). Triplicate PCACO and PATDCO measurements were recorded during phenylephrine-induced vasoconstriction and nitroprusside-induced vasodilation (Phase-2). RESULTS: Mean bias (limits of agreement: LOA) (L/min), percentage bias (PB), and percentage error (PE) were 0.62 (-0.11 to 1.35), 16%, and 19% for TI5 ; and 0.33 (-0.25 to 0.91), 9%, and 16% for TI10 . Mean bias (LOA), PB, and PE were 0.22 (-0.63 to 1.07), 6%, and 23% during phenylephrine; and 2.12 (0.70-3.55), 43%, and 29% during nitroprusside. Mean angular bias (radial LOA) values were 2° (-10° to 14°) and -1° (-9° to 6°) for TI5 and TI10 , respectively (Phase-1), and 38° (5°-71°) (Phase-2). CONCLUSIONS AND CLINICAL IMPORTANCE: Although TI10 slightly improves the agreement and trending ability between TPTDCO and PATDCO in comparison to TI5 , both volumes can be used for TPTDCO in replacement of PATDCO . Vasodilation worsens the agreement between PCACO and PATDCO . Because of PCACO 's poor agreement and trending ability with PATDCO during SVR changes, this method has limited clinical application.en
dc.description.affiliationFaculdade de Medicina, Universidade Estadual Paulista, Botucatu, São Paulo, Brazil
dc.description.affiliationFaculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, UNESP, Botucatu, São Paulo, Brazil
dc.format.extent941-950
dc.identifierhttp://dx.doi.org/10.1111/jvim.13984
dc.identifier.citationJournal of veterinary internal medicine, v. 30, n. 4, p. 941-950, 2016.
dc.identifier.doi10.1111/jvim.13984
dc.identifier.file2-s2.0-85028281742.pdf
dc.identifier.issn1939-1676
dc.identifier.scopus2-s2.0-85028281742
dc.identifier.urihttp://hdl.handle.net/11449/170061
dc.language.isoeng
dc.relation.ispartofJournal of veterinary internal medicine
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectIndicator dilution cardiac output
dc.subjectMonitoring
dc.subjectPulse contour analysis
dc.titleComparison of Transpulmonary Thermodilution and Calibrated Pulse Contour Analysis with Pulmonary Artery Thermodilution Cardiac Output Measurements in Anesthetized Dogsen
dc.typeArtigo
dspace.entity.typePublication

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-85028281742.pdf
Tamanho:
1022.55 KB
Formato:
Adobe Portable Document Format
Descrição:

Coleções