Calibration of a Harmonic State Estimation to Assess the Connection of Solar PV Systems in Distribution Networks

dc.contributor.authorBermeo, Alex Daniel Lozado
dc.contributor.authorBermeo, Diego Pául Guachichullca
dc.contributor.authorAsanza, Sergio Patricio Zambrano [UNESP]
dc.contributor.authorMatute, Geovanny Armando Matute
dc.contributor.authorFernández, Juan Sanango
dc.contributor.authorBaquero, John Fredy Franco [UNESP]
dc.contributor.institutionSchool of Electrical Engineering
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionCENTROSUR Electric Distribution Utility
dc.contributor.institutionElectronics and Telecommunications
dc.date.accessioned2025-04-29T20:15:59Z
dc.date.issued2023-01-01
dc.description.abstractThis paper presents an analysis of the distribution system harmonic behavior when a photovoltaic (PV) system is connected at the low-voltage network. Through harmonic power flow simulations in the Open Distribution System Simulator (OpenDSS), harmonic impact at the point common coupling is studied. To reduce the harmonic analysis, simulations are carried out using a simplified equivalent for utility and customer. In order to model a more realistic distribution system, it is necessary to calibrate the harmonic sources before connecting the PV system. The harmonic state estimation method implemented in combination with the simulator is used to calibrate the utility harmonic voltage sources. After calibration, the harmonic levels at medium-voltage are verified. Results for a case study using quality measurements performed by Ecuadorian CENTROSUR electric utility show that the simulated harmonic levels are similar to those measured. It also shows that a PV system does not produce power quality problems.en
dc.description.affiliationUniversity of Cuenca School of Electrical Engineering
dc.description.affiliationSão Paulo State University - UNESP CENTROSUR Electric Distribution Utility Department of Electrical Engineering Department of Planning
dc.description.affiliationCENTROSUR Electric Distribution Utility Department of Planning
dc.description.affiliationUniversity of Cuenca Department of Electrical Engineering Electronics and Telecommunications
dc.description.affiliationSão Paulo State University - UNESP Department of Electrical Engineering, SP
dc.description.affiliationUnespSão Paulo State University - UNESP CENTROSUR Electric Distribution Utility Department of Electrical Engineering Department of Planning
dc.description.affiliationUnespSão Paulo State University - UNESP Department of Electrical Engineering, SP
dc.identifierhttp://dx.doi.org/10.1109/ETCM58927.2023.10309054
dc.identifier.citationECTM 2023 - 2023 IEEE 7th Ecuador Technical Chapters Meeting.
dc.identifier.doi10.1109/ETCM58927.2023.10309054
dc.identifier.scopus2-s2.0-85179508995
dc.identifier.urihttps://hdl.handle.net/11449/309585
dc.language.isoeng
dc.relation.ispartofECTM 2023 - 2023 IEEE 7th Ecuador Technical Chapters Meeting
dc.sourceScopus
dc.subjectHarmonic analysis
dc.subjectharmonic current
dc.subjectharmonic state estimation
dc.subjectharmonic voltage
dc.subjectPV system