Publicação: Copper nanoparticles and reduced graphene oxide modified a glassy carbon electrode for the determination of glyphosate in water samples
dc.contributor.author | Setznagl, Sarah [UNESP] | |
dc.contributor.author | Cesarino, Ivana [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2020-12-12T01:13:55Z | |
dc.date.available | 2020-12-12T01:13:55Z | |
dc.date.issued | 2020-01-01 | |
dc.description.abstract | A novel electrochemical sensor based on a glassy carbon electrode, modified with reduced graphene oxide and copper nanoparticles (GC/rGO-CuNPs), was developed for the determination of glyphosate herbicide (GLY) by differential pulse voltammetry (DPV). The proposed material was synthesised by a chemical method and characterised by scanning electron microscopy (SEM) and cyclic voltammetry (CV). Voltammetric tests showed that the anodic peak at 30 mV, due to the Cu0 to Cu2+ oxidation process, decreased linearly with small additions of GLY; this inhibition was used to quantify the pesticide content in water by DPV. The GC/rGO-CuNPs electrode was evaluated and optimised for the determination of GLY in tap water samples without any pretreatment, achieving a linear response in the range of 0.1 to 1.1 µmol L−1 with a detection limit of 0.19 µmol L−1 (R2 = 0.9996). This study provides a new application for graphene-based sensors and a promising alternative for GLY analysis. | en |
dc.description.affiliation | Institute of Biosciences Sao Paulo State University (UNESP) | |
dc.description.affiliation | School of Agriculture Sao Paulo State University (UNESP) | |
dc.description.affiliationUnesp | Institute of Biosciences Sao Paulo State University (UNESP) | |
dc.description.affiliationUnesp | School of Agriculture Sao Paulo State University (UNESP) | |
dc.identifier | http://dx.doi.org/10.1080/03067319.2020.1720667 | |
dc.identifier.citation | International Journal of Environmental Analytical Chemistry. | |
dc.identifier.doi | 10.1080/03067319.2020.1720667 | |
dc.identifier.issn | 1029-0397 | |
dc.identifier.issn | 0306-7319 | |
dc.identifier.scopus | 2-s2.0-85078892758 | |
dc.identifier.uri | http://hdl.handle.net/11449/198477 | |
dc.language.iso | eng | |
dc.relation.ispartof | International Journal of Environmental Analytical Chemistry | |
dc.source | Scopus | |
dc.subject | copper nanoparticles | |
dc.subject | electrochemical sensor | |
dc.subject | Glyphosate | |
dc.subject | reduced graphene oxide | |
dc.title | Copper nanoparticles and reduced graphene oxide modified a glassy carbon electrode for the determination of glyphosate in water samples | en |
dc.type | Artigo | |
dspace.entity.type | Publication |